General
• 规格:Power requirements
• To RPM4-E-DWT::12 V dc 1.2 A
• To AC to DC power supply::100 V ac to 240 V ac, 50/60 Hz
• 规格:Temperature range
• Storage::- 20 °C to 70 °C
• Operating::10 °C to 40 °C
• 规格:Relative Humidity
• Storage::0 % to 100 %
• Operating::0 % to 70 %
• 规格:Weight
• 1 Q-RPT::12 kg (26 lb) approximate
• 2 Q-RPT::14 kg (30 lb) approximate
• 规格:Dimensions
• E-DWT footprint::41.4 cm W x 37.1 cm D (16.3 in x 14.6 in)
• E-DWT height::26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height
• Pressure range:Up to 200 MPa (30k psi), depending on configuration
• Operating medium:All 6531 and 6532 E-DWT Kits are shipped dry, standard preparation. Can be filled with di-ethyl-hexyl sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol and distilled water or mineral oil.
• Reservoir capacity:300 cc (18 in3)
• Variable volume displacement:3 cc (0.18 in3), 200 MPa (30,000 psi) maximum
• Filling and priming pump displacement:3.7 cc (0.23 in3)
• TEST pressure connection:DH500 female, 200 MPa (30k psi) maximum working pressure. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. Adapter maximum working pressure is 140 MPa (20k psi). Note: DH500 is a gland and collar type fitting for 6 mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc.
• 规格:Pressure Limits
• Maximum Working Pressure::Range of RPM4-E-DWT monitor’s Hi Q-RPT
• Maximum priming pump pressure::700 kPa (100 psi)
• Maximum Working Pressure::with Lo Q-RPT selected: Range of RPM4-E-DWT monitor’s Lo Q-RPT
• Communication ports::RS-232 (COM1, COM2)
• 规格:Pressure measurement
• Warm up time:15 minute temperature stabilization recommended from cold power up
• Normal Operating Temperature Range:10 °C to 40 °C (50 °F to 104 °F)
• Resolution:Default: 0.01 % of active range User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger
• Precision1:200 MPa (30,000 psi) ranges: ± 0.018 % of reading or 0.0036 % of Q-RPT span, whichever is greater All other ranges: ± 0.018 % of reading or 0.0018 % of Q-RPT span, whichever is greater
• 规格:Predicted Stability2
• One year::± 0.0075 % of reading
• Two year::± 0.015 % of reading
• 规格:Measurement Uncertainty3
• One year::200 MPa (30,000 psi) ranges: ± 0.02 % of reading or 0.004 % of Q-RPT span, whichever is greater All other ranges: ± 0.02 % of reading or 0.002 % of Q-RPT span, whichever is greater
• Two year::200 MPa (30,000 psi) ranges: ± 0.025 % of reading or 0.005 % of Q-RPT span, whichever is greater All other ranges: ± 0.025 % of reading or 0.0025 % of Q-RPT span, whichever is greater
型号与选件
• 6531-14M:
• 6531-7M:
• 6531-20M:
• 6531-40M:
• 6531-70M:
• 6531-140M: