MSOX4154G 示波器 1.5GHz 详细指标
Benchtop Oscilloscopes
一、InfiniiVision 4000 X-Series Performance Specifications
DSO and MSO
4000A/G X-Series oscilloscopes
4000 X-Series specification overview
4022A/G 4024A/G 4032A/G 4034A/G 4052A/G 4054A/G 4104A/G
4154A/G
Bandwidth1 (–3 dB) 200 MHz 350 MHz 500 MHz 1 GHz
1.5 GHz2
All-channel real-time bandwidth 200 MHz 350 MHz 500 MHz 1 GHz
1 GHz
Calculated rise time (10 to 90%) ≤ 1.75 ns ≤ 1 ns ≤ 700 ps ≤ 450 ps ≤
300 ps
条件:Display size and type 12.1-inch high-definition capacitive touch display
MSOX 2 + 16 4 + 16 2 + 16 4 + 16 2 + 16 4 + 16 4 + 16 4 +
16
Maximum sample rate 5 GSa/s half channel
2.5 GSa/s all channel
Maximum memory depth 4 Mpts half channels
2 Mpts all channels
Waveform update rate >
1 million waveforms per second
System bandwidth with N2894A standard
passive probe 200 MHz 200 MHz 350 MHz 350 MHz 500 MHz 500 MHz 700 MHz
700 MHz
Hardware bandwidth limits Approximately
20 MHz (selectable)
条件:1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30- minute warm -up period and
2. 1.5 GHz real time bandwidth in half -channel mode or full channel equivalent time mode.
3. 1 mV/div and 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV
Input impedance Selectable: 1 MΩ ± 1% (16 pF), 50 Ω
± 1.5%
Input sensitivity range 200 MHz ~ 500 MHz models
1 mV/div to 5 V/div3 (1 MΩ and 50 Ω)
1 and 1.5 GHz models: 1 mV/div to 5 V/div3 (1 MΩ)
1 mV/div to 1 V/div (50 Ω)
Vertical resolution 8 bits (measurement resolution is
12 bits with averaging)
Maximum input voltage 1 MΩ
135 Vrms
Probing technology allows testing of higher voltages. For example, the included N2894A
10:1
probe supports testing up to 300 Vrms
Use this instrument only for measurements within its specified measurement category (not rated
for CAT II, III, IV). No transient overvoltage allowed 50 Ω 50 Ω: ≤
5 Vrms max
Trigger In 300 Vrms, mains isolated voltages only (No Measurement Category Allowed)
DC vertical gain accuracy1
± 2.0% full scale2
DC vertical offset accuracy ± 0.1 div ± 2 mV
± 1% of offset setting
Channel-to-channel isolation 200 MHz~1 GHz ≥
40 dB from DC to maximum specified bandwidth of each mode
1.5 GHz ≥ 40 dB from DC to 1 GHz, ≥
35 dB from 1 to 1.5 GHz
Offset range ± 5 V (< 10 mV/div), ± 20 V (10 to 200 mV/div), ± 75 V (>
200 mV/div)
± 10 °C from firmware calibration.
for 1 mV/div and 2 mV/div sensitivity setting.
Digital input channels 16 digital (D0 to D15. Pod 1: D7 ~ D0, Pod
2: D15 ~ D8)
Thresholds Threshold per pod
Threshold selections TTL (+1.4 V)
5 V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod)
User-defined threshold range
± 8.0 V in 10 mV steps
Maximum input voltage
± 40 V peak
Threshold accuracy1 ± (100 mV +
3% of threshold setting)
Maximum input dynamic range
± 10 V about threshold
Minimum voltage swing
500 mVpp
Input impedance 100 kΩ
± 2% at probe tip
Horizontal system analog channels 4022A/G 4024A/G 4032A/G 4034A/G 4052A/G 4054A/G 4104A/G
4154A/G
Time base range 2 ns/div to 50 s/div 1 ns/div to 50 s/div
500 ps/div to 50 s/div
Time base accuracy1
± 10 ppm
Time base delay time range Pre-trigger Greater of 1 screen width or 200 μs (400 μs in interleaving mode)
Channel-to-channel deskew range
± 100 ns
Δ Time accuracy (using cursors) ± 0.001% of reading ± 0.16% screen width
± 30pS
On channels 1 and 2 only. Z Blanking on Ext Trigger Input
1.4 V threshold
Bandwidth: Maximum bandwidth. Phase error at 1 MHz: < 0.5 degree Time base
200 ns/div to
50 ms/div
条件:1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30- minute warm -up period
Minimum detectable pulse width
2 ns
Channel-to-channel skew 2 ns (typical)
3 ns (maximum)
Acquisition system 4022A/G 4024A/G 4032A/G 4034A/G 4052A/G 4054A/G 4104A/G
4154A/G
Maximum analog channels sample rate 5 GSa/s half channel interleaved
2.5 GSa/s all channels
Analog channels equivalent sample rate N/A
128 GSa/s
Maximum analog channels record length 4 Mpts half channel interleaved
2 Mpts all channel
Maximum digital channels sample rate
1.25 GSa/s
and
± 10 °C from firmware calibration.
Acquisition system 4022A/G 4024A/G 4032A/G 4034A/G 4052A/G 4054A/G 4104A/G
4154A/G
Peak detect Capture glitches as narrow as
200 ps at all time base settings
Averaging Selectable from 2, 4, 8, 16
64, ... to 65,536
High resolution Real-time boxcar averaging reduces random noise and effectively increases vertical resolution
Segmented Segmented memory optimizes available memory for data streams that have long dead times
between activity. Maximum segments = 1000. Re-arm time =
1 μs (minimum time between
trigger events). Re-arm time when used with the zone touch trigger =
65 μs or faster (typical)
Roll Displays the waveform moving across the screen from right to left. Available at the time base
50 ms/div or slower
Digitizer Allows independent selection of sample rate and memory depth
Equivalent time 1 GHz and 1.5 GHz models only.
7.8 ps fine interpolator resolution yields a maximum effective
sample rate of 128 GSa/s
Trigger sources Analog channel (1 ~ 4), digital channel (D0 ~ D15), line, external, WaveGen (1
2, or Mod)
Trigger modes Normal Requires trigger event for oscilloscope to trigger
Auto Triggers automatically in absence of trigger event
Single Front panel button that triggers only once on a trigger event. Press [Single] button again for
oscilloscope to find another trigger event, or press [Run] front-panel button to trigger
条件:1. Denotes warranted specifications, all others are typical. Specifications are valid after a 30- minute warm -up period
AC AC coupled trigger, cutoff frequency: < 10 Hz (internal); <
50 Hz (external)
HF reject High-frequency reject, cutoff frequency ~
50 kHz
LF reject Low-frequency reject, cutoff frequency ~
50 kHz
Noise reject Adds hysteresis to the trigger circuitry. Selectable OFF or ON, decreases sensitivity
2x
Trigger holdoff range
40 ns to 10.00 s
Trigger sensitivity (internal)1 200 MHz ~ 1 GHz < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div
0.6 di
1.5 GHz DC to 1 GHz: < 10 mV/div: Greater of 1 div or 5 mV; ≥ 10 mV/div
0.6 div
1 to 1.5 GHz: < 10 mV/div: Greater of 1.5 div or 5 mV; ≥ 10 mV/div
1.0 div
Trigger sensitivity (external)1 ± 1.6 V 40 mVpp DC to 100 MHz, 70 mVpp
100 to 200 MHz
± 8 V 200 mVpp DC to 100 MHz, 350 mVpp
100 to 200 MHz
Trigger level range Any channel
± 6 div from center screen
External 8 V range = ± 8 V, 1.6 V range =
± 1.6 V
and
± 10 °C from firmware calibration.
Supported 模式: 正常, 峰值 detect, 高分辨率
条件:Edge Trigger on a rising, falling, alternating, or either edge of analog channels, digital channels, or an external signal.
Also works simultaneously with the serial decodes and mask limit test.
触发开 rising 或 falling line 信号
条件:Edge then edge (B trigger) Arm on a selected edge, wait a specified time, then trigger on a specified count of another selected edge.
Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value, or inside
• Minimum duration setting: 2 ns (500 MHz, 1 GHz, 1.5 GHz), 4 ns (350 MHz)
6 ns (200 MHz)
• Maximum duration setting
10 s
Pattern Trigger when a specified pattern of high, low, and don’t-care levels on any combination of analog, digital, or
trigger channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as a valid
• Minimum duration setting: 2 ns (500 MHz, 1 GHz, 1.5 GHz), 4 ns (350 MHz)
6 ns (200 MHz)
• Maximum duration setting
10 s
Or Trigger on any selected edges from available sources (analog and digital channels only up to 500 MHz)
Rise/fall time Trigger on rise-time or fall-time edge speed violations (< or >) based on user-selectable threshold. Select from (<
• Minimum: 1 ns (500 MHz, 1 GHz, 1.5 GHz model), 2 ns (350 MHz model)
3 ns (200 MHz model)
Nth edge burst Trigger on the Nth (1 to 65535) edge of a pulse burst. Specify idle time (10 ns to 10 s) for framing
Runt Trigger on a positive runt pulse that fails to exceed a high-level threshold. Trigger on a negative runt pulse that
fails to exceed a low-level threshold. Trigger on either polarity runt pulse based on two threshold settings. Runt
triggering can also be time-qualified (< or >) with a minimum time setting of 2 ~
6 ns and maximum time setting of
10 s
• Minimum time setting: 2 ns (500 MHz, 1 GHz, 1.5 GHz), 4 ns (350 MHz)
6 ns (200 MHz)
Setup and hold Trigger on setup/hold violations. Setup time can be set from –7 to 10 s. Hold time can be set from 0 s to
10 ns. Minimum window (setup time + hold time) must be
3 ns or greater
Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC,
条件:conditions (parity, word, gap, word or gap, all), all bits (eye), all 0 bits, all 1 bits
FlexRay (Option) Trigger on frame ID or specific error condition, along with cycle-base and repetition-cycle filtering. Can also
I²C (Option) Trigger at a start/stop condition or user defined frame with address and/or data values. Also trigger on missing
Enhanced video (HDTV) (Option) Trigger on lines and fields of enhanced and HDTV standards (480p/60, 567p/50, 720p/50, 720p/60
1080p/24
1080p/25, 1080p/30, 1080p/50, 1080p/60, 1080i/50
1080i/60)
ARINC429 (Option) Trigger and decode on ARINC429 data. Trigger on word start/stop, label, label + bits, label range, error
CAN (Option) Trigger on CAN (controller area network) version
2.0A,2.0B, and CAN-FD (Flexible Data-rate) signals. Trigger on
the start of frame (SOF), the end of frame (EOF), data frame ID, data frame ID and data (non-FD), data frame ID
and data (FD), remote frame ID, remote or data frame ID, error frame, acknowledge error, from error, stuff error,
CRC error, spec error (ack or form or stuff or CRC), all errors, BRS Bit (FD), CRC delimiter bit (FD), ESI bit active
(FD), ESI bit passive (FD), overload frame., message, message and signal (non-FD), message and signal (FD,
trigger on specific events such as BSS, TSS, FES, and wake up
acknowledge, address with no acq, restart, EEPROM read, and 10-bit write
I²S (Option) Trigger on
2’s complement data of audio left channel or right channel (=, ≠, <, >, > <, < >, increasing value, or
LIN (Option) Trigger on LIN (local interconnect network) sync break, sync frame ID, frame ID and data, parity error, or
条件:error, data length error, sample error, all errors, sleep frame, wakeup pulse.
error conditions (parity, sync, Manchester)
CXPI (Option) Trigger on the start of frame (SOF), the end of frame (EOF), PTYPE, frame ID, data and info frame ID, data and
info frame ID (long frame), CRC field error, parity error, inter-byte space error, inter-frame space error, framing
MIL-STD1553 (Option) Trigger on MIL-STD 1553 signals on data word start/stop, command/status start/stop, RTA, RTA +
11 bits, and
SPI (Option) Trigger on SPI (serial peripheral interface) data pattern during a specific framing period. Supports positive and
negative chip select framing as well as clock Idle framing and user-specified number of bits per frame. Supports
UART/RS232/422/485 (Option) Trigger on Rx or Tx start bit, stop bit, data content, or parity error
USB (Option) Trigger on start of packet (SOP), end of packet (EOP), suspend1, resume1, reset1, packets (token, data,
handshake, or special), and errors (PID, CRC5, CRC16, glitch, bit stuff1, SE11). Supports USB
2.0 low speed, full
speed, and hi-speed (hi-speed is supported on
1 GHz and 1.5 GHz models only)
SENT (Option) Trigger on SENT bus. start of fast channel message, start of slow channel message, fast channel SC and data,
slow channel message ID, slow channel message ID and data, tolerance violation, fast channel CRC error, slow
channel CRC error, all CRC errors, pulse period error, successive sync pulses error (1/64)
User-definable Manchester/NRZ (Option)
Trigger on start-of-frame (SOF), bus value, and Manchester errors
USB PD (Option) Trigger on preamble, EDP, ordered sets, preamble errors, CRC errors, header content (control messages, data
条件:Automatic measurements Measurements continuously updated with statistics. Cursors track last selected measurement.
DC vertical accuracy/cursors2 Single cursor accuracy: ± [DC vertical gain accuracy + DC vertical offset accuracy +
0.21%
full scale] Dual cursor accuracy: + [DC vertical gain accuracy +
0.42% full scale]3
Cursors
2 pairs of XY cursors
Automatic measurement of positions, ∆X
1/∆X, ∆Y, and ∆Y/∆X
Select up to four measurements from the list below
Vertical “Y at X” Peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot, average- N
cycles, average- full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles, AC
RMS- full screen (standard deviation), ratio (RMS1/RMS2)
Time at edge Period, frequency, counter, + width, - width, burst width, duty cycle, bit rate, rise time, fall time,
延迟, 相位, X · 最小 Y, X · 最大 Y
Count Positive pulse count, negative pulse count, rising edge count, falling edge count
Mixed slew rate Area- N cycles, area- full screen
条件:Automatic measurement logging Available via BenchVue 1. Suspend, resume, reset, bit stuff error, and SE1 error are USB 2.0 low and full speed only. 2. 1 mV/div and 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV/div and 2 mV/div sensitivity setting.
3. Denotes warranted specifications, all others are typical. Specifications are valid after a 30- minute warm -up period and
± 10 °C from firmware calibration temperature
Resolution 5 digits. Up to 8 digits with an external reference
10 MHz input
Mask limit test option Mask limit test capability that provides easy, fast pass/fail comparison of a signal under test to
a predefined mask template or auto-mask template. Predefined mask templates or edits to an
auto-mask template can be made via a simple text editor. >
270,000 mask tests per second
Measurement limit test (Option) Provide pass/fail analysis on selected parametric measurements based on user-defined
maximum and minimum limits with selectable stop-on-failure capability
编号 math 功能 Four (显示 one · 时间)
Arithmetic Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root, absolute, common log,
natural log, exponential, base
10 exponential, LP filter, HP filter, averaged value, smoothing, envelope, magnify
max hold, min hold, measurement trend, chart logic bus (timing or state) , chart serial signal (CAN, CAN FD, LIN,
FFT Up to 64 kpts resolution. FFT window types: Hanning, flat top, rectangular, Blackman-Harris, Bartlett
Display
12.1-inch capacitive touch/gesture enabled color TFT LCD
Resolution 800 (H) x
600 (V) pixel format (screen area)
Graticules 8 vertical divisions by
10 horizontal divisions with intensity controls
Maximum waveform update rate >
1,000,000 wfm/s
Persistence Off, infinite, variable persistence (100 ms to 60 s)
Intensity gradation
64 intensity levels
USB 2.0 hi-speed host port USB 2.0 hi-speed host ports x3, two front and one real panel. Supports memory devices, printers, keyboards and
USB 2.0 hi-speed device port One USB 2.0 hi-speed device port on rear panel. USB Test and Measurement Class (USBTMC) compatible
LAN port
10/100Base-T port on rear panel. LXI IPv6 extended function
Web remote control VNC Web interface (via major Web browsers)
Video out port SVGA out on rear panel. Connect oscilloscope display to an external monitor or projector
GPIB port An external GPIB-to-LAN interface is available from ICS.
10 MHz out/in BNC connector on the rear panel. Supported modes: Off
10 MHz out, or reference signal mode (10 MHz in)
Trigger out BNC connector on the rear panel. Supported modes: triggers, mask, waveform generator
1 sync pulse, and
waveform generator
2 sync pulse
Dual-channel WaveGen built-in function/arbitrary waveform generator (specifications are typical)
WaveGen 输出 Two (前面板-面板 BNC 连接器)
Both waveform generator outputs can be frequency tracked, amplitude tracked, or completely tracked.* A
generator’s output can be inverted to create a differential signal
Waveforms Sine, square, ramp, pulse, DC, noise, sine cardinal (sinc), exponential rise, exponential fall, cardiac, Gaussian
Modulation Modulation is available on channel 1 only. Modulation is not available when tracking mode is enabled. Modulation
Carrier waveforms: Sine, Ramp, Sine Cardinal, Exponential Rise, Exponential Fall, and Cardiac.Modulation
Modulation: Sine, Square, Ramp
Modulation frequency: 1 Hz to 20 kHz Depth
0% to 100%
Modulation: Sine, Square, Ramp
Modulation frequency
1 Hz to 20 kHz
Minimum carrier frequency
10 Hz
Deviation
1 Hz to carrier frequency or (2e12/carrier frequency), whichever is smaller
条件:1. Only the following combination of wave shapes can be frequency tracked or completely tracked:
1) Sine, ramp, sine cardinal, cardiac, and Gaussian pulse.
2) Square wave and pulse
3) Exponential rise and exponential fall.
4) Arbitrary
1. Full resolution is not available at output due to internal attenuator stepping.
2. Sinc cardiac and Gaussian pulse: ± 1.25 V into Hi -Z; ± 625 mV into 50 Ω.
Modulation
50% duty cycle square wave
Hop frequency
2 x FSK rate to 10 MHz
Dual-channel WaveGen built-in function/arbitary waveform generator (specifications are typical)
Sine Frequency range
0.1 Hz to 20 MHz
Amplitude flatness
± 0.5 dB (relative to 1 kHz)
Harmonic distortion
–40 dBc
Spurious (non harmonics)
–40 dBc
Total harmonic distortion
1%
Square wave/pulse Frequency range
0.1 Hz to 10 MHz
Duty cycle resolution Larger of 1% or 10 ns
Rise/fall time
19 ns (10 to 90%)
Asymmetry (at 50% DC) ± 1%
± 5ns
Ramp/triangle wave Frequency range
0.1 Hz to 200 kHz
Variable symmetry
0 to 100%
Pulse Frequency range
0.1 Hz to 10 MHz
Pulse with resolution
10 ns
Edge time Fixed at 19 ns (not variable)
Noise Bandwidth
20 MHz typical
Sine cardinal (Sinc) Frequency range
0.1 Hz to 1.0 MHz
Exponential rise/fall Frequency range
0.1 Hz to 5.0 MHz
Cardiac Frequency range
0.1 Hz to 200.0 kHz
Gaussian pulse Frequency range
0.1 Hz to 5.0 MHz
Arbitrary Waveform length
1 to 8,192 points
Amplitude resolution
10 bits (including sign bit)1
Repetition rate
0.1 Hz to 12 MHz
Frequency Sine wave and ramp accuracy 130 ppm (frequency <
10 kHz)
50 ppm (frequency >
10 kHz)
Square wave and pulse accuracy [50 + frequency/200] ppm (frequency <
25 kHz)
50 ppm (frequency ≥
25 kHz)
Resolution
0.1 Hz or 4 digits, whichever is larger
Amplitude Range: Minimum 20 mVpp if |offset| ≤
0.5 Vpp into Hi-Z2
10 mVpp if |offset| ≤ 0.5 Vpp into
50 Ω2
Range: Maximum 10 Vpp except, 9 Vpp if Sinc or Cardiac
7.5 Vpp if Gaussian pulse
into Hi-Z; 5 Vpp/4.5 Vpp into
50 Ω
Resolution
100 μV or 3 digits, whichever is higher
Accuracy 1.5% (frequency =
1 kHz)
Dual-channel WaveGen built-in function/arbitary waveform generator (specifications are typical)
DC offset Range ± 5 V into Hi-Z, except ± 4 V if sine wave
± 2.5 V if sinc, cardiac
or Gaussian pulse into Hi-Z ± 2.5 V into Hi-Z, except ± 2 V if sine wave, ± 1.25 V if sinc, cardiac, or Gaussian pulse into
50 Ω
Resolution Larger of 250 uV or 3 digits
Accuracy (waveform modes) ± 1.5% of offset setting ± 1% of amplitude
± 1 mV
Accuracy (DC mode) ± 1.5% of offset setting
± 3 mV
Main output Impedance
50 Ω typical
Source Analog channels only (1-4)
Resolution ACV/DCV
3 digits
Counter frequency
5.5 digits
Measuring rate
100 times/second
Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements
Range meter Graphical display of most recent measurement, plus extrema over the previous
3 seconds
Power line consumption Maximum
120 W
Power voltage range 100 to 120 V, 50/60/400 Hz; 100 to 240 V
50/60 Hz
Environmental rating 0 to 50 °C
3000 m max
Maximum Relative Humidity (non-condensing)
95%RH up to 40 °C
From 40 °C to 50 °C, the maximum % Relative Humidity follows the line of constant dew point
Electromagnetic compatibility Meets EMC Directive (2004/108/EC), meets or exceeds IEC
61326-1:2005/EN
61326-1:2006 Group
1 Class A requirement
IEC 61000-4-2/EN
61000-4-2
IEC 61000-4-3/EN
61000-4-3
IEC 61000-4-4/EN
61000-4-4
IEC 61000-4-5/EN
61000-4-5
IEC 61000-4-6/EN
61000-4-6
IEC 61000-4-11/EN
61000-4-11
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS
Safety CAN/CSA-C22.2 No. 61010-1-12, UPD1: 2015, UPD2: 2016, AMD1: 2018, CAN/CSA-C22.2 No.
61010-2-030:18
UL Std. No. 61010-1 3rd Ed. (2018); UL Std. No.
61010-2-030-2nd Ed. (2018)
Vibration Meets IEC60068-2-6 and MIL-PRF-28800; class
3 random
Publication title Publication number
Power Software Package - Data Sheet
5992-3925EN
Automotive Software Package - Data Sheet
5992-3912EN
Embedded Software Package - Data Sheet
5992-3924EN
Aero Software Package - Data Sheet
5992-3910EN
USB Software Package - Data Sheet
5992-3920EN
Ultimate Bundle Software Package - Data Sheet
5992-3918EN
Shock Meets IEC 60068-2-27 and MIL-PRF-28800; class 3 random; (operating 30 g, ½ sine. 11 ms duration
3 shocks/
axis along major axis, total of 18 shocks)
Dimensions (W x H x D) 454 mm x 275 mm x
156 mm
Weight Net: 6.3 kg (13.9 lbs), shipping
11.4 kg (25 lbs)
Kensington style lock Rear-panel security slot connects to standard Kensington-style lock
Reference waveform display
4 internal waveforms or USB thumb drive
Save formats Setup (*.scp), 8- or 24-bit bitmap image (*.bmp), PNG
24-bit image (*.png), CSV data (*.csv), ASCII XY data
(*.csv), binary data (*.bin), lister data (*.csv), reference waveform data (*.h5), multi-channel waveform data (*.h5),
mask (*.mask), arbitrary waveform data (*.csv), power harmonics data (*.csv), USB signal quality (*.html & *.bmp)
Max USB flash drive size Supports industry-standard flash drives
Set ups without USB flash drive
10 internal setups
Included standard with oscilloscope
Calibration Soft copy of Certificate of Calibration (CoC) with measurement results downloadable from
Probes One per channel N2894A
700 MHz passive probe (10:1 attenuation)
N2756A 16-digital-channel MSO cable (1 per oscilloscope included on all MSO models and DSOXPERFMSO)
Localized interface English, Chinese (simplified and traditional), French, German, Italian, Japanese, Korean, Portuguese, Russian,
Spanish localized front panel overlays, interface, and built-in help system
DSOX4WAVEGEN2
DSOXPERFMSO MSO upgrade: Add
16
cable delivered separately
DSOX4SECA Enhanced Security option License only
Publication title Publication number
D4000GENB Standard on G models, option on A models – Embedded Software Package: I2C, SPI, UART (RS232/422/485), I2S, and USB PD
serial trigger and decode, plus Measurement Limit Testing, Mask Limit Testing, Frequency Response Analysis (Bode plots), and
D4000AUTB Automotive Software Package: CAN, CAN FD, LIN, FlexRay, SENT, CXPI, PSI5 (User-definable Manchester), and User-definable
NRZ serial trigger & decode, plus Measurement Limit Testing, Mask Limit Testing and Frequency Response Analysis (Bode plots)
D4000AERB Aero Software Package: MIL-STD 1553 and ARINC 429 serial trigger and decode, plus Measurement Limit Testing, Mask Limit
Testing, Frequency Response Analysis (Bode plots), and Enhanced Video Analysis
D4000USBB1, 2 USB Software Package: USB 2.0 Low-, Full-, & Hi-speed, USB PD trigger & decode, plus USB
2.0 Signal Quality Test
Measurement Limit Testing, Mask Limit Testing, and Frequency Response Analysis (Bode plots)
D4000PWRB Power Software Package: Power quality, current harmonics, switching loss, turn-on/off time, transient response, loop response,
PSRR, & more, plus Measurement Limit Testing, Mask List Testing, Frequency Response Analysis (Bode plots), and USB PD
D4000BDLB Ultimate Bundle Software Package: I2C, SPI, UART, I2S, CAN, CAN FD, LIN, FlexRay, CXPI, PSI5 (User-definable Manchester),
User-definable NRZ, USB 2.0 low-, full-, & hi-speed1, USB PD, MIL-STD 1553, and ARINC
429 serial trigger & decode, plus USB
2.0 Signal Quality Test2, Power Analysis, Measurement Limit Testing, Mask Limit Testing, Frequency Response Analysis (Bode
plots), Enhanced Video Analysis
条件:Process description 1 Place order for a license-only upgrade with a Keysight sales partner. 2 For software packages, you will receive a paper or electronic .pdf entitlement certificate. For bandwidth upgrades only, you will receive a stick-on label document indicating upgraded bandwidth specification in addition to a paper entitlement certificate.
oscilloscope model number and serial number unit. 4 Receive the licensed file and installation instructions via email. 5 Copy license file (.lic extension) from email to a USB drive and follow instructions in email to install the purchased bandwidth upgrade or measurement application on the oscilloscope.
3 Use entitlement certificate containing instructions and certificate number needed to generate a license file for a particular
4000 X-Series
6 For bandwidth upgrades only, attach bandwidth upgraded stick-on labels to front and rear panels of the oscilloscope. Model number and serial
number of the oscilloscope do not change
Return-to-Keysight Service Center Bandwidth Upgrades
4000 X-Series bandwidth upgrade models
条件:specification. Model number and serial number of the oscilloscope do not change.
DSOX4B2T32U 200 MHz ~ 350 MHz
2 ch Service center
DSOX4B2T34U 200 MHz ~ 350 MHz
4 ch Service center
DSOX4B5T104U 500 MHz ~ 1 GHz
4 ch Service center
DSOX4B1T154U 1 GHz ~ 1.5 GHz
4 ch Service center
DSOX4B2T52U 200 MHz ~ 500 MHz
2 ch Service center
DSOX4B2T54U 200 MHz ~ 500 MHz
4 ch Service center
DSOX4B2T104U 200 MHz ~ 1 GHz
4 ch Service center
DSOX4B2T154U 200 MHz ~ 1.5 GHz
4 ch Service center
DSOX4B3T104U 350 MHz ~ 1 GHz
4 ch Service center
DSOX4B3T154U 350 MHz ~ 1.5 GHz
4 ch Service center
DSOX4B5T154U 500 MHz ~ 1.5 GHz
4 ch Service center
Process description 1 Place order for a return-to-Keysight service center bandwidth upgrade product to a Keysight sales partner. Serivce Center installation, calibration, shipment costs are in addition to bandwidth upgrade product price. 2 Keysight Business Center will contact you regarding process and timing of the service center installation. Continue to use oscilloscope until
contacted again later when parts are available at service center.
3 Ship the oscilloscope per provided instructions to service center.
4 Service center ships back upgraded oscilloscope with stick-on labels applied to front and rear panels indicating upgraded bandwidth
Confidently Covered by Keysight Services
Prevent delays caused by technical questions, or system downtime due to instrument maintenance and
repairs with Keysight Services. Keysight Services are here to support your test needs with expert
technical support, instrument repair and calibration, software support, training, alternative acquisition
以上指标摘自厂家官方数据手册,完整定义、测试条件与保证值口径以手册为准。完整指标、测试条件与定义口径请见产品页「软件和手册 | 白皮书」栏目中的官方数据手册。