是德科技 | KEYSIGHT
FieldFox系列N9933C C 3kHz至4GHz手持式微波频谱分析仪 120MHz带宽 详细指标
将精准测量带入现场
条件:Accuracy, when locked to GPS ± 0.010 ppm (nominal)
Accuracy, when GPS antenna is disconnected ± 0.4 ppm (nominal)1
| Models | Frequency | range |
|---|
| N991xC N9912C | 3 kHz to | 4/6.5/10 GHz |
| N9913C | 3 kHz to | 4 GHz |
| N9914C | 3 kHz to | 6.5 GHz |
| N9915C | 3 kHz to | 10 GHz |
| Frequency reference | -10 to | 55 °C |
| Accuracy | ± 0.9 ppm (spec) + aging | |
| ± 0.5 ppm (typical) + aging | | |
| Aging Rate | ± 1 ppm/yr for | 20 years (spec), will not exceed ± 3.5 ppm |
条件:System impedance 50 Ω (nominal), 75 Ω with appropriate adapter and calibration kit 1 The maximum drift expected in the frequency reference applicable when the ambient temperature changes ±5°C from the temperature when the GPS signal was last connected.
3 kHz to 1.49961 GHz
0.34 Hz
> 1.49961 to 2.99961 GHz
0.67 Hz
> 2.99961 GHz to 5.99961 GHz
1.34 Hz
> 5.99961 GHz to 10 GHz
2.68 Hz
Data points or resolution 101, 201, 401, 601, 801, 1001, 1601, 4001
10,001
Arbitrary number of points settable through front panel and SCPI
IF bandwidth2
3 Hz, 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz
100 kHz
2 VNA mode only. Recommend using averaging in CAT mode.
High power in the N991xC refers to the analyzer’s target output power level when the Power Setting is
• N991xC: For a 58.4 MHz to 10 GHz frequency sweep, the analyzer achieves an
8 dBm power level
Low power level for N991xC analyzers flattens at -50 dBm across the entire frequency band and is the
Max leveled power in the N991xC refers to the maximum leveled (flattened) power achieved across the
designated frequency range. An example
• N991xC: For a
58.4 MHz to 10 GHz frequency sweep with the analyzer configured to measure all four
S-parameters, needing both ports 1 and 2, the maximum power the analyzer can be set to is
7 dBm.
> 150 kHz to 300 kHz
-2
> 800 kHz to 3.45 MHz
2
> 3.45 MHz to 58.4 MHz
5
条件:Max leveled output power (dBm) Nominal Nominal
3 kHz to 10 GHz -50 dBm (flattened)
±0.5 dB
> 3.45 MHz to 58.4 MHz
5
CAT High, low, and manual. Default (preset) power is manual
−15 dBm.
Manual power is flattened
VNA High, low, and manual. Default (preset) power is manual
−15 dBm.
Power settable in 1 dB steps across power range. Flat power, in 1 dB steps, is available across the whole
Power level accuracy1 Typical
N991xC Port 1 or Port
2 at -20 dBm
> 300 kHz to 10 GHz
± 0.5 dB
N991xC Port 1 or Port
−50 dBm ≤ P < max leveled power
> 10 MHz to 10 GHz
± 0.45 dB
条件:Measurement stability over temperature Nominal Nominal
3 kHz to 30 kHz - 86 - 87
> 30 kHz to 1 MHz - 110 - 115
> 1 MHz to 10 MHz 102 117 101
116
> 10 MHz to 4 GHz 106 118 103
118
> 4 GHz to 6.5 GHz 104 117 104
120
> 6.5 GHz to 10 GHz 104 116 102
117
N991xC Frequency Magnitude (dB/ºC) Phase (deg/ºC)
3 kHz to 100 kHz ± 0.6
± 2.9
> 100 kHz to 10 GHz ± 0.011
± 0.4
CAT N991xC
Return loss, 3 kHz to 10 GHz, 1-port cal, 1001 points
461 µs/pt
Distance-to-fault, 100-meter cable, 1-port cal, 1001 points
512 µs/pt
VNA N991xC
S11 and S21, 30 kHz to 10 GHz, enhanced response cal
100 kHz
200 μs/pt
1 Power levels are calibrated based on PNA-X tuned receiver for the entire frequency range.
2 System dynamic range is measured in the factory with loads on the test ports after a thru normalization.
3 For CAT mode, “Insertion loss (2- port)”, decrease listed dynamic range specifications by
20 dB, as CAT mode IFBW is fixed at
10 kHz. Can obtain full dynamic range by using S21 measurement in VNA mode with 100 Hz IFBW.
System dynamic range2,3 (dB), high power, 300 Hz IFBW, 100-point average, Port 1 or Port
2 (-10 to 55°C)
Frequency S12 Spec S12 Typical S21 Spec S21 Typical
Trace noise, high power, 300 Hz IFBW, Port 1 or Port
2 Specifications (-10 to 55⁰C)
N991xC Frequency Magnitude (dB rms) Phase (deg rms)
3 kHz to 50 kHz 0.00521
0.0721
> 50 kHz to 5 GHz2 0.0011
0.011
> 5 GHz to 10 GHz 0.0015
0.015
N991xC Frequency Port 1 or Port
2
250 kHz to 1.25 GHz +8 dBm
0.20 dB compression
> 1.25 GHz to 5 GHz +8 dBm
0.15 dB compression
> 5 GHz to 10 GHz +8 dBm
0.10 dB compression
Maximum input level Port 1 or Port
2
N991xC Average CW power DC
+25 dBm, 0.3 watts
±40 VDC
Immunity to interfering signals
N991xC Nominal
On carrier frequency
+7 dBm
Offset from carrier frequency > 1 MHz
+7 dBm
1 Typical values
10 Hz IFBW.
2 Excludes frequency range between
5 MHz and 25 MHz.
CAT measurements Distance-to-fault (dB), Distance-to-fault (Lin)
Cable loss (1-port)
Insertion loss (2-port) (requires option
211)
TDR (Lin rho) (requires option 215), TDR (ohm) (requires option
215)
TDR & DTF (requires option
215)
CAT 模式平均 Set 扫描时间 · seconds
Distance-to-fault Available in CAT mode. Standard on N991xC analyzers.
Range = velocity factor x speed of light x (# of points -1) / freq. span x
2
# of points auto coupled according to start and stop distance entered.
Resolution = range / (# of points
-1)
Dispersion compensation for waveguide: Yes
Return loss, log magnitude
-500 to 500 dB
Log magnitude resolution
0.01 dB
VNA Transmission/Reflection (T/R) S11, S21 magnitude and phase (requires option
210)
VNA S-parameters S11, S21, S22, S12 magnitude and phase
(N9912C requires option NAx, other N991xC requires options
210 and
211)
Number of traces Four traces available: Tr1, Tr2, Tr3, Tr4
Quad-trace overlay (all four traces on one graticule)
VNA trace formats Log magnitude, linear magnitude, VSWR, phase, Smith chart, polar,
group delay, unwrapped phase, real impedance, imaginary impedance,
扫描触发斜率 Positive, negative
Sweep trigger delay
0 to 10 seconds
Averaging Sweep: 2 to 1000; Point
2 to 500
Smoothing Computes the moving average of adjacent data points. Smoothing
aperture defines the trace width (number of points) to be averaged.
Minimum aperture
0.05% of frequency span
Maximum aperture
25% of frequency span
Scale Autoscale, scale, reference level, reference position
Autoscale: Automatically selects scale resolution and reference value to
Autoscale all: Scales all visible traces
S11, log magnitude
-500 to 500 dB
Log magnitude resolution
0.01 dB
Phase
-180 to +180 degrees (unwrapped phase can show larger values)
Phase resolution
0.01 degrees
Phase offset
-360 to +360 degrees
Magnitude offset
-100 to +100 dB
Trace math Vector division or subtraction of current linear measurement values and
Port extension For both port 1 and port
2, delay settings. Port extensions apply to all
Marker functions Peak, Next Peak, Peak Left, Peak Right, Mkr→Center, Mkr→Delay, Min
Search, Peak Excursion, Peak Threshold, Target, Bandwidth (BW, Q,
Loss), Tracking CAT mode only: Tracking
3 peaks (CAT mode)
Marker types Normal, delta, data trace and memory trace markers
标记耦合 On/关 (耦合 between 迹线)
Frequency blanking Security level: none, high. If high, all frequency information is blanked
out. An instrument preset is required to re-enable the frequency
Display data Display data, memory, data and memory, or data math
CAT and VNA mode calibrations
FieldFox analyzers offer three tiers of calibrations, thus providing users with different levels of calibration
CalReady is the most basic calibration and is sufficient for a quick pass/fail or go/no go verification. Every
FieldFox is calibrated at the factory, at test ports
1 and 2, at room temperature. CalReady can be applied
either as an “enhanced response CalReady” or a “2-port CalReady.” The default setting is
2-port
CalReady, so correction is applied to both ports. A user preference allows user to change the CalReady
methodology to enhanced response CalReady
A 30-minute warm-up period is recommended for a quick test. A
60-minute warm-up is necessary for
If CalReady is the basis for most measurements, the annual cal cycle must be followed, as the CalReady
Standard calibrations are the most accurate calibrations offered in FieldFox. FieldFox’s calibration engine
is based on Keysight’s flagship PNA calibration engine, and as such, offers many of the standard
calibrations. FieldFox supports both coaxial and waveguide calibrations. The table below lists the
commonly used calibrations
Keysight recommends a 30-minute warm-up period for standard calibrations. For ultimate in stability and
accuracy, a
90-minute warm-up period is necessary.
Simultaneous magnitude and phase correction of frequency response errors
for either reflection or transmission measurements. Isolation corrects for
crosstalk errors. 1-port OSL (Port 1) 1-port OSL (Port
2)
Traditional
1-port calibration for reflection measurements. Corrects for
Reverse enhanced response
Corrects for frequency response and source match. Partial correction for load
match for low-loss reciprocal devices
QSOLT (2-port) QSOLT or Quick short-open-load-thru is FieldFox’s default recommended
calibration for insertable devices. Full
12-term error correction. Requires fewer
connections, compared to traditional SOLT (4 compared to 7). Corrects for
directivity, source match, reflection frequency response, load match, and
FieldFox’s default recommended calibration for non-insertable devices. Full
12-
term error correction. Beneficial for characterizing non-insertable devices such
as Type-N to 3.5 mm, or female-female devices. Corrects for directivity, source
match, reflection frequency response, load match, and transmission frequency
TRL TRL or thru-reflect-line compensates for directivity, reflection, and transmission
frequency response in both the forward and reverse directions.
** Note: FieldFox does not offer the traditional SOLT calibration. Instead, it offers the more accurate Full
2- port (unknown thru)
FieldFox’s guided calibration wizard
条件:kit. FieldFox’s calibration wizard ensures a valid calibration selection.
FieldFox’s calibration wizard recommends a calibration type and calibration kit based on selected
parameters and connector types. Alternatively, users can select their own calibration type and calibration
Interpolation error correction
With any type of accuracy enhancement applied, interpolated mode recalculates the error coefficients
when the test frequencies are changed. The number of points can be increased or decreased, and the
start/stop frequencies can be changed, but the resulting frequency span must be a subset of the original
The FieldFox firmware supports the following connector types by default. Add other connector types with
Type-N
75 ohm WR-15 WR-112
7/16 WR-19 WR-137
TNC WR-22 WR-159
Type-F WR-28 WR-187
7 mm WR-34 WR-229
3.5 mm WR-42 WR-284
2.92 mm WR-51 WR-650
2.4 mm WR-62
1.85 mm WR-75
FieldFox S-parameter measurement uncertainties
The configurations listed below include measurement uncertainties based on ISO GUM methodology
FieldFox model Calibration kit Calibration type DUT connector Uncertainty
N991xC 85518A or 85519A Full
2-port calibration Type-N Spec
N991xC 85054D Full
2-port calibration Type-N Spec
N991xC N7554A Full
2-port calibration Type-N Spec
N991xC N4690D Full
2-port calibration Type-N Spec
条件:Corrected performance table calculated using uncertainties with a coverage factor of 2.
minute warm-up time. Includes uncertainties due to drift, noise, compression, and dynamic accuracy.
N9912/13/14/15C, 85518A or 85519A, Full
2-port Cal, DUT: Type-N, Spec
Corrected performance (dB) 0.003 to 500 MHz 0.5 to 2 GHz 2 to 8 GHz
8 to 10 GHz
Reflection tracking ±00011 ±0.02 ±0.036
±0.009
Transmission tracking1 ±0.044 ±0.087 ±0.21
±0.21
Uncertainty plots: power level of -20 dBm
10 Hz IF bandwidth, no averaging, battery saver off, and 60-
Coverage factor of 1 applied to uncertainties, for ease of comparison with other industry handheld
条件:1. Load match and transmission tracking are typical values.
Corrected performance table calculated using uncertainties with a coverage factor of 2.
minute warm-up time. Includes uncertainties due to drift, noise, compression, and dynamic accuracy.
Transmission uncertainty (S21, S12)
Reflection uncertainty (S11, S22)
N9912/13/14/15C, 85054D, Full
2-port Cal, DUT: Type-N, Spec
Corrected performance (dB) 0.003 to 500 MHz 0.5 to 2 GHz 2 to 8 GHz
8 to 10 GHz
Reflection tracking ±0.00068 ±0.0019 ±0.0053
±0.0073
Transmission tracking1 ±0.004 ±0.012 ±0.038
±0.042
Uncertainty plots: power level of -20 dBm
10 Hz IF bandwidth, no averaging, battery saver off, and 60-
Coverage factor of 1 applied to uncertainties, for ease of comparison with other industry handheld
条件:Corrected performance table calculated using uncertainties with a coverage factor of 2.
minute warm-up time. Includes uncertainties due to drift, noise, compression, and dynamic accuracy.
Transmission uncertainty (S21, S12)
Reflection uncertainty (S11, S22)
1 Load match and transmission tracking are typical values.
N9912/13/14/15C, N7554A ECal, Full
2-port Cal, DUT: Type-N, Spec
Corrected performance (dB) 0.003 to 500 MHz 0.5 to 2 GHz 2 to 8 GHz
8 to 10 GHz
Reflection tracking ±0.0067 ±0.0036 ±0.054
±0.076
Transmission tracking1 ±0.063 ±0.086 ±0.14
±0.16
Uncertainty plots: power level of -20 dBm
10 Hz IF bandwidth, no averaging, battery saver off, and 60-
Coverage factor of 1 applied to uncertainties, for ease of comparison with other industry handheld
条件:Corrected performance table calculated using uncertainties with a coverage factor of 2.
minute warm-up time. Includes uncertainties due to drift, noise, compression, and dynamic accuracy.
Transmission uncertainty (S21, S12)
Reflection uncertainty (S11, S22)
1 Load match and transmission tracking are typical values.
N9912/13/14/15C, N4690D ECal Option 0DC, Full
2-port Cal, DUT: Type-N, Spec
Corrected performance (dB) 1 0.003 to 500 MHz 0.5 to 2 GHz 2 to 8 GHz
8 to 10 GHz
Reflection tracking ±0.05 ±0.03 ±0.03
±0.03
Transmission tracking2 ±0.064 ±0.063 ±0.063
±0.099
Uncertainty plots: power level of -20 dBm
10 Hz IF bandwidth, no averaging, battery saver off, and 60-
Coverage factor of 1 applied to uncertainties, for ease of comparison with other industry handheld
条件:1. When applied power exceeds -5 dBm, calibration results will be degraded from the performance indicated in this table.
2. Load match and transmission tracking are typical values.
Corrected performance table calculated using uncertainties with a coverage factor of 2.
minute warm-up time. Includes uncertainties due to drift, noise, compression, and dynamic accuracy.
Transmission uncertainty (S21, S12)
Reflection uncertainty (S11, S22)
N9912/13/14/15C, N4690D ECal Option 003, Full
2-port Cal, DUT: Type-N, Spec
Corrected performance (dB) 1 0.3 to 2 MHz 2 to 10 MHz
10 to 500
MHz 0.5 to 2 GHz 2 to 8 GHz
8 to 10 GHz
Directivity 30 40 45 45 40
40
Source match 28 35 40 43 40
40
Load match2 28 35 40 37 37
33
Reflection tracking ±0.12 ±0.07 ±0.05 ±0.03 ±0.03
±0.03
Transmission tracking2 ±0.12 ±0.07 ±0.05 ±0.063 ±0.063
±0.098
Uncertainty plots: power level of -20 dBm
10 Hz IF bandwidth, no averaging, battery saver off, and 60-
Coverage factor of 1 applied to uncertainties, for ease of comparison with other industry handheld
条件:1. When applied power exceeds -5 dBm, calibration results will be degraded from the performance indicated in this table.
2. Load match and transmission tracking are typical values.
vector voltmeter sections applies to the capabilities available in the following models:
Transmission uncertainty (S21, S12)
Reflection uncertainty (S11, S22)
TDR Cable Measurements (Option
215)
The performance listed in TDR cable measurements, VNA time domain, mixed-mode S-parameters and
条件:See FieldFox Configuration Guide for option information. Many capabilities listed in this Data Sheet
FieldFox RF & microwave (combination) analyzers N9912C, N9913C, N9914C, N9915C
条件:The TDR cable option adds time domain reflectometry (TDR) measurements to FieldFox’s CAT mode.
FieldFox’s TDR measurements are based on an inverse Fourier transform of the frequency-domain data.
TDR measurements are useful in not only identifying the location of faults along cables, but also the
nature of the fault. Resistive, inductive and capacitive faults will each have a different response. These
differences help engineers and technicians’ trouble-shoot line faults.
X-axis: distance (meters or feet)
VNA Time Domain (Option
010)
In time-domain mode, FieldFox computes the inverse Fourier transform of the frequency-domain data to
Gating Start, stop, center, span, and on/off
Numbers of points, velocity vector, line loss, window shape, independent control for all four traces
Low-pass step Low-pass step is similar to a traditional time domain reflectometer (TDR)
stimulus waveform. It is used to measure low-pass devices. The
frequency-domain data should extend from DC (extrapolated value) to a
条件:Low-pass impulse Low-pass impulse response is used to measure low-pass devices.
Bandpass impulse The bandpass impulse simulates a pulsed RF signal and is used to
The windowing function can be used to filter the frequency domain data and thereby reduce overshoot and ringing in
Windows Minimum, medium and maximum, manual entry of Kaiser Beta and
The gating function can be used to selectively remove reflection or transmission time domain responses. In
converting back to the frequency domain, the effects of the responses outside the gate are removed. The results can
Gate shapes 最大值, wide, 正常, 最小值
条件:Mixed-mode S-parameters are also known as balanced measurements. Not available for N9912C.
Mixed-Mode S-Parameters (Option
212)
Scc11 Common mode reflection
Sdd11 Differential mode reflection
Scd11 Differential mode stimulus, common mode response
Sdc11 Common mode stimulus, differential mode response
FieldFox’s mixed-mode S-parameter measurements require the use of the default factory calibration or a
user 2-port calibration. So, the FieldFox analyzer must be equipped with 2-port measurement functionality
to measure mixed-mode S-parameters. Mixed-mode S-parameters are an extension of the VNA
条件:device measurements. The results are shown on a large display in digital format.
Vector Voltmeter (VVM) (Option
308)
With vector voltmeter mode, you can characterize the difference between two measurements easily. The
zeroing function allows you to create a reference signal and characterize the difference between two
| Model | Options | Frequency | range |
|---|
| N9912C NA4 and 308 | 3 kHz to 4 GHz | | |
| NA6 and 308 | 3 kHz to 6.5 GHz | | |
| NAX and 308 | 3 kHz to 10 GHz | | |
| N9913C | 308 | 3 kHz to | 4 GHz |
| N9914C | 308 | 3 kHz to | 6.5 GHz |
| N9915C | 308 | 3 kHz to | 10 GHz |
| Setup parameters 1-port cable trimming Reflection (S11 or S22 measurement), magnitude and phase | 2-port transmission Transmission or S21 measurement, magnitude, and phase | | |
| A/B and B/A Ratio of two receivers or channels, magnitude, and phase – Need an external signal | | | |
Setup parameters 1-port cable trimming Reflection (S11 or S22 measurement), magnitude and phase
Options
2-port transmission Transmission or S21 measurement, magnitude, and phase
A/B and B/A Ratio of two receivers or channels, magnitude, and phase – Need an external signal
IF bandwidth
10 Hz to 100 kHz or 3 Hz to 30 kHz
Must zero before measuring DUT. Recommend using a high-quality power splitter or 6 dB attenuators to
条件:The performance listed in this section applies to the spectrum analyzer capabilities available in the
N991xC 100 kHz to 2 GHz
± 0.2
Spectrum Analyzer (Option SAx on N9912C or
Option
233 on Combination Analyzers)
适用型号 FieldFox RF combination analyzers N9912C, N9913C, N9914C, N9915C
条件:See FieldFox Configuration Guide for option information. Many capabilities listed in this Data Sheet
FieldFox RF spectrum analyzers N9933C, N9934C, N9935C
条件:Accuracy, when locked to GPS ±0.01 ppm (nominal)
Accuracy, when GPS antenna is disconnected ±0.4 ppm (nominal) 2
RBW centering: 5% x RBW, FFT mode (nominal) 16% x RBW, step mode (nominal) 1 The spectrum analyzer is tunable to 0 Hz or DC.
Model Option Frequency range
1
N9914C 233
3 kHz to 6.5 GHz
N9915C 233
3 kHz to 10 GHz
Frequency reference
-10 to 55 °C
Accuracy
±0.9 ppm (spec) + aging
±0.5 ppm (typical) + aging
Aging rate ±1 ppm/yr for 20 years (spec), will not exceed
±3.5 ppm
Frequency readout accuracy (start, stop, center, marker) ± (readout frequency x frequency reference accuracy +
RBW centering +
0.5 x horizontal resolution)
Horizontal resolution = frequency span / (trace points – 1)
2 The maximum drift expected in the frequency reference applicable when the ambient temperature changes
± 5°C from the
Accuracy ± (marker frequency x frequency reference accuracy + counter resolution)
Range 0 Hz (zero span)
10 Hz to maximum frequency range of instrument
Accuracy ± (2 x RBW centering + horizontal resolution) for detector = Normal
Sweep time readout Measured value of the time required to complete a sweep from start to finish,
including time to tune receiver, acquire data, and process trace.
9 updates per second
autocoupled
25 updates per second
Span = 10 GHz, RBW =
1 MHz
条件:Center frequency tune and transfer1 Nominal
Approximately
2 updates per second
101 points, zero span
80 ms
101 points, 1 MHz span
75 ms
101 points, 100 MHz span
75 ms
Readout Entered value representing trace horizontal scale range
触发斜率 Positive 边沿, negative 边沿
Trigger delay Range
-150 ms to 10 s
Auto trigger Forces a periodic acquisition in the absence of a trigger event
Trigger position (zero span) Controls horizontal position of the pulse edge; use sweep time to zoom into
条件:graticule 1 Within full frequency range of instrument, not band dependent.
Range: 0 to 10, integer steps; 0 is left edge of graticule
10 is right edge of
Operating frequency range
20 MHz to maximum instrument frequency
All spans 101, 201, 401, 601, 801
1001 (defaults to 401)
Arbitrary 2 to 20,001 settable through soft key “# Points” or SCPI
Zero span 10 Hz to 1 MHz
± 5%
Non-zero span 1 Hz to 100 kHz
± 1%
Measurement range DANL to +20 dBm
Input attenuator range
0 to 40 dB, in 5 dB steps
Frequency range Full band (3 kHz to maximum frequency of instrument)
Gain +20 dB
3 kHz to 10 GHz
最大安全输入电平 Average CW 功率 DC
条件:Resolution bandwidth (RBW) Nominal
Frequency range +25 dBm, 0.3 watts
±40 VDC
Range (-3 dB bandwidth)
Zero span 10 Hz to 5 MHz 1, 3
10 sequence
Non-zero span 1 Hz to 5 MHz (>5MHz)2 1, 1.5, 2, 3, 5, 7.5, 10 sequence < 300 kHz
300
kHz, 1 MHz, 3 MHz
5 MHz (Other RBWs may
be set depending on settings)
Step keys change RBW in 1, 3
10 sequence
Selectivity (−60 dB / −3 dB)
4:1
Video bandwidth (VBW) 1 Hz to 5 MHz 1, 1.5, 2, 3, 5, 7.5
10 sequence
0.01 to 100 dB/division in 0.01 dB steps
Scale units dBm, dBmV, dBµV, dBmA, dBµA, W, V, A, dBµV/m, dBµA/m, dBG, dBT
50 MHz absolute amplitude accuracy (dB)
10 dB attenuation, input signal -40 to -5 dBm, peak detector, preamplifier off1
300 Hz RBW, all settings auto-coupled. No warm-up
条件:Total absolute amplitude accuracy (dB) with preamp off 10 dB attenuation, input signal -15 to -5 dBm, peak detector, 300 Hz RBW, all settings auto-coupled, includes frequency response uncertainties. No warm-up required.
Spec (-10 to 55 °C) Typical (-10 to 55 °C)
1 The spec and typical values, with preamp on, are identical to that with preamp off, but the input signal levels are
-40 to - 20 dBm .
Frequency Spec (-10 to 55 °C) Typical (-10 to 55 °C)
N991xC/N993xC
with preamplifier off 3 kHz to 100 kHz ±1.00
±0.20
≥ 100 kHz to 15 MHz ±0.80
±0.15
≥ 15 MHz to 500 MHz ±0.80
±0.15
≥ 500 MHz to 4.5 GHz ±1.00
±0.15
≥ 4.5 GHz to 10 GHz ±1.00
±0.20
Total absolute amplitude accuracy (dB) with preamp on (Option
235 required and turned on)
20 dB attenuation, input signal -25 to -15 dBm, peak detector
300 Hz RBW, all settings auto-coupled, includes frequency response
uncertainties. No warm-up required
条件:Resolution bandwidth switching uncertainty Nominal
RF input VSWR Nominal 1 MHz to 2.7 GHz 1.9 :1
Frequency Spec (-10 to 55 °C) Typical (-10 to 55 °C)
N991xC/N993xC
with preamplifier on 3 kHz to 100 kHz ±1.20
±0.25
≥ 100 kHz to 15 MHz ±0.80
±0.25
≥ 15 MHz to 500 MHz ±0.80
±0.15
≥ 500 MHz to 4.5 GHz ±1.00
±0.15
≥ 4.5 GHz to 10 GHz ±1.00
±0.15
For signals not at center frequency
0.7 dB peak-to-peak
> 2.7 GHz to 7.5 GHz
1.8 :1
> 7.5 GHz to 10 GHz
1.9 :1
Detectors Normal, positive peak, negative peak, sample, average (RMS)
States Clear/write, max hold, min hold, average, view, blank
Number of averages
1 to 10,001
Number 4: all four can be active simultaneously and in different states
Audio beep Volume and tone change with signal strength
Marker table Display
6 markers
Marker→ Peak, next peak, peak left, peak right, center frequency, reference
Tune frequency, for AM/FM tune and listen
Marker properties Peak criteria: peak excursion, peak threshold
条件:measured at non-zero frequency span
Input terminated, RMS detection, log averaging
0 dB input attenuation, reference level of -20 dBm, normalized to 1 Hz RBW
条件:Residual responses (dBm) Nominal
Input related responses (dBc) Nominal
Tuned frequency (f) Excitation frequency Spur frequency Nominal
Other spurious responses (dBc) Nominal
1 dB gain compression point (P1dB) 1 - (dBm) Nominal
Second harmonic distortion Nominal
Spec (-10 to 55 °C)
Typical (-10 to 55 °C)
Spec (-10 to 55 °C)
Typical (-10 to 55 °C) 3 kHz to 100 kHz -121 -134 -142
-156
≥ 100 kHz to 1 MHz -121 -134 -148
-157
≥ 1 MHz to 15 MHz -134 -141 -157
-162
≥ 15 MHz to 2.6 GHz -139 -148 -158
-165
≥ 2.6 GHz to 4.5 GHz -140 -147 -157
-163
≥ 4.5 GHz to 7.5 GHz -138 -145 -156
-162
≥ 7.5 GHz to 10 GHz -134 -143 -152
-160
Input terminated preamp off
0 dB attenuation
-30 dBm signal at mixer input (excludes frequencies listed below)
-85
f < 2.6 GHz, f ≥ 7.5 GHz to 10 GHz f +
2 *3.56625GHz
f -80
f ≥ 2.6 GHz to 7.5 GHz f + 2*
9.3375GHz
f -80
fOffset = frequency offset of excitation frequency from tuned frequency (f)
f < 2.6 GHz, f ≥ 7.5 GHz to 10 GHz f + fOffset f - n * fOffset, (n=1,2, 3,…)
-75
f + fOffset f - 2 * (5.625MHz ± fOffset)
-70
f ≥ 2.6 GHz to 7.5 GHz f + fOffset f - n * fOffset, (n=1, 2, 3,…)
-75
f + fOffset f - 2 * (5.625MHz ± fOffset)
-70
LO related spurs 3 kHz to 10 GHz
-75
Battery charging sideband
-70
1 Excludes
3.3114375 GHz at -98 dBm.
N991xC, N993xC 10 MHz to 100 MHz
0
-30 dBm signal at mixer input SHI (dBm) Distortion (dBc)
N991xC, N993xC 10 to 50 MHz +45
-75
≥ 50 MHz to 1.3 GHz +50
-80
Third 阶互调失真 (TOI) 典型值 (dBm)
条件:Spur free dynamic range (dB) at 2.4 GHz 2/3 (TOI – DANL) Nominal
Two -15 dBm signals
100 kHz spacing at mixer input (-10 to 55 °C)
N991xC, N993xC 50 MHz to 500 MHz
+6.5
(+8 @ room temperature)
1 Tested with two -tone signals: the first tone signal at –30 dBm mixer input and the second tone with 40 MHz spacing from the
first tone at mixer input. Step up the power of the second tone until 1 dB compression has been achieved.
0 dB attenuation
span of 5 kHz, and 30 Hz RBW.
Distortion and noise limited (10 Hz RBW) dynamic range
SSB phase noise at 1 GHz center frequency
条件:Phase noise at different center frequencies (nominal) 1 Tested at 2.99 MHz.
Dynamic range versus offset frequency versus RBW (nominal)1 1 For 1 MHz RBW, the sideband observed may degrade the dynamic range to -68 dBc
SSB phase noise at 1 GHz
Offset Spec (-10 to 55 °C) Typical (-10 to 55 °C)
条件:The performance listed in this section applies to the signal path of “Baseband” for the spectrum/signal
analyzer. Switch to the “Baseband” mode to optimize the analyzer’s performance if the input signal is
below
6.5 MHz. Preamp is not applicable to the baseband signal path.
以上指标摘自厂家官方数据手册,完整定义、测试条件与保证值口径以手册为准。完整指标、测试条件与定义口径请见产品页「软件和手册 | 白皮书」栏目中的官方数据手册。