DSOX6004A 示波器 1GHz 详细指标
Benchtop Oscilloscopes
DSOX/MSO
6000 X-Series digital storage/mixed signal oscilloscopes
6000 X-Series specification overview
Half channel bandwidth 1 (–3 dB) 1 GHz 2.5 GHz 4 GHz
6 GHz
Full channel bandwidth 1 (–3 dB) 1 GHz 2.5 GHz 4 GHz
4 GHz
Full channel equivalent time bandwidth 1 (–3 dB) N/A N/A N/A
6 GHz
Calculated rise time (10 to 90%) ≤ 350 ps ≤ 140 ps ≤ 112.5 ps ≤
75 ps
Maximum sample rate 20 GSa/s half channels
10 GSa/s full channels
Maximum memory depth 4 Mpts half channels
2 Mpts all channels
Display size and type
12.1-inch capacitive multi-touch/gesture-enabled display
Waveform update rate >
450,000 waveforms per second
Typical noise floor at 1 mV/div, 50 Ω 115 μVrms 150 μVrms 150 μVrms
210 μVrms
Hardware bandwidth limits 1 MΩ 20 MHz, 200 MHz (selectable per channel) 50 Ω 20 MHz, 200 MHz, 1.5 GHz
3 GHz (selectable per channel)
Input impedance Selectable: 1 MΩ ± 1% (14 pF), 50 Ω
± 3%
Input sensitivity range 1 MΩ 1 mV/div to 5 V/div 2 (200 MHz bandwidth limit at ≤
2 mV/div)
50 Ω 1 mV/div to 1 V/div
2
Vertical resolution 8 bits (measurement resolution is
12 bits with averaging)
Maximum input voltage 1 MΩ 30 Vrms or ±40 Vmax (DC + Vpeak); Probing technology allows testing of higher voltages. The included N2894A 10:1 probe supports
300 Vrms or ±400 Vmax (DC +
条件:1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30- minute warm -up period and ± 10
°C from firmware calibration temperature. 2. 1 mV/div is a magnification of 2 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting.
No transient overvoltage allowed in either the
50Ω or 1 MΩ path, with or
without probes. Use this instrument only for measurements within its specified
measurement category (not rated for CAT II, III, IV). 50 Ω 50 Ω
± 5Vpk max
DC vertical gain accuracy
1
± 3 div
1.5% of full scale (typical)
± 4 div: 2.5% of full scale (warranted)
2
DC vertical offset accuracy ± 0.1 div ± 2 mV ± 1% of offset setting (valid for an offset of ≤
± 12 divisions)
Channel-to-channel isolation ≥ 100:1 (DC to 1 GHz), ≥ 30:1 (>
1 GHz)
Offset range 1 MΩ ± 5 V (1 to < 10 mV/div), ± 20 V (10 to ≤ 200 mV/div), ± 100 V (> 200 mV/div) 50 Ω ± 12 div or ± 0.8 V, whichever is smallest (≤ 100 mV/div) ± 12 div or ± 4 V, whichever is smallest (>
100 mV/div)
± 8 divisions from center screen (≤ 100 mV/div)
2nd harmonic distortion of - 40 dbc
± 4 divisions from center screen (> 101 mV/div)
2nd harmonic distortion of - 23 dbc
(For a 10:1 probe on the 1 MΩ input, vertical scaling is multiplied by
10)
50 Ω
± 8 divisions from center screen
Noise floor at 50 Ω
1 mV/div 115 µVrms
150 µVrms
10 mV/div 330 µVrms
355 µVrms
100 mV/div 3.15 mVrms
3.25 mVrms
1 V/div 31.5 mVrms
32.5 mVrms
ESD tolerance
± 2 kV (on input BNCs)
Digital input channels 16 digital (D0 to D15. Pod 1: D7 ~ D0, Pod
2: D15 ~ D8)
Thresholds Threshold per pod
Threshold selections TTL (+1.4 V)
5V CMOS (+2.5 V), ECL (–1.3 V), user-defined (selectable by pod)
User-defined threshold range
± 8.0 V in 10-mV steps
Maximum input voltage
± 40 V peak
Threshold accuracy 1 ± (100 mV +
3% of threshold setting)
Maximum input dynamic range
± 10 V about threshold
Minimum voltage swing
500 mVpp
Input impedance 100 kΩ
± 2% at probe tip
Horizontal system analog channels 1 GHz 2.5 GHz 4 GHz
6 GHz
Time base range
500 ps/div to 50
s/div 100 ps/div to 50 s/div
100 ps/div to 50
s/div
100 ps/div to 50 s/div
Time base accuracy
± 1.6 ppm + aging factor
(1 year: ± 0.5 ppm, 2 years: ± 0.7 ppm, 5 years: ± 1.5 ppm, 10 years
± 2.0 ppm)
Time base resolution
2.5 ps
Pre-trigger Greater of 1 screen width or 50 µs
Channel-to-channel deskew range
± 100 ns
Δ time accuracy (using cursors) Same channel: ± (time base accuracy x reading) ± (0.0016 x screen width)
± 10 ps
Channel-to-channel: ± (time base accuracy x reading) ± (0.0016 x screen width)
± 15 ps
Modes Main, zoom, roll, XY
XY On channels 1 and 2 only. Z blanking on ext trigger input
1.4 V threshold
Bandwidth: maximum bandwidth. Phase error at 1 MHz: <
0.5 degree
条件:1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30- minute warm -up period and ± 10
Minimum detectable pulse width
2 ns
Channel-to-channel skew 2 ns (typical)
3 ns (maximum)
Acquisition system 1 GHz 2.5 GHz 4 GHz
6 GHz
Maximum analog channels sample rate 20 GSa/s half channel interleaved
10 GSa/s all channel
Analog channels equivalent sample rate Not available
400 GSa/s
≤ 2 GSa/s 4 Mpts half channel interleaved
2 Mpts all channel
> 2 GSa/s 1 Mpts half channel interleaved
500 kpts all channel
Maximum digital channels sample rate 2 GSa/s half pods interleaved
1 GSa/s all pods
Maximum digital channels record length 4 Mpts half pods interleaved
2 Mpts all pods
Peak detect Analog channels: Capture glitches as narrow as 500 ps (half channel)
1 ns (all channel)
Digital channels: Capture glitches as narrow as 500 ps (half pods)
1 ns (all pods)
Averaging Selectable from 2, 4, 8, 16
64, ... to 65,536
Real-time boxcar averaging reduces random noise and effectively increases vertical
resolution 12 bits: ≥ 20 μs/div at 2 GSa/s or ≥
50 μs/div at 1 GSa/s
Segmented memory optimizes available memory for data streams that have long dead
times between activity. Maximum segments = 1000. Re-arm time = As fast as
1 μs
Real time Default mode (>
135,000 waveforms/sec)
Max update rate Enhanced real-time mode for the fastest waveform update rate of >
450,000
waveforms/sec. Up to 2 GSa/s. Returns to a normal real-time mode at >
2 GSa/s
Equivalent Available with 6-GHz bandwidth license. The time base must be at 20 ns/div or faster.
2.5-
ps fine interpolator resolution yields a maximum effective sample rate of 400 GSa/s
Roll Displays the waveform moving across the screen from right to left. Available at time bases
50 ms/div or slower
XY Shows the volts-versus-volts display. Time base can be set from 200 ns/div to 50 ms/div
Trigger sources Analog channel (1~4), digital channel (D0~D15), line, external, WaveGen (1
2, or Mod
Normal Requires trigger event for oscilloscope to trigger
Auto Triggers automatically but not synchronized to the input in absence of trigger event
Front panel button that triggers only once on a trigger event. Press Single button again for
oscilloscope to find another trigger event, or press Run front panel button to trigger
条件:Trigger bandwidth Edge 500 MHz, 1 GHz, 2.5 GHz models: bandwidth of oscilloscope. 4-GHz and 6-GHz models:
AC AC-coupled trigger, cutoff frequency: < 10 Hz (internal); <
50 Hz (external)
HF reject High-frequency reject, cutoff frequency ~
50 kHz
LF reject Low-frequency reject, cutoff frequency ~
50 kHz
Noise reject Adds hysteresis to the trigger circuitry; selectable OFF or ON, decreases sensitivity
2x
Trigger holdoff range
40 ns to 10.00 s
Trigger jitter <
1.0-ps rms with the jitter-free trigger
< 3.0-ps rms without the jitter-free trigger
3.5 GHz
Other modes Bandwidth of oscilloscope or 1 GHz, whichever is smaller
Trigger sensitivity (internal) 1 1 GHz bandwidth ≤
10 mV/div DC to 1 GHz Greater of 1 div or 5 mVpp
> 10 mV/div DC to 1 GHz
0.6 div
条件:1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30- minute warm -up period and ± 10
≤ 10 mV/div DC to 2 GHz Greater of 1 div or 5 mVpp
2.0 to 3.5 GHz Greater of 1.5 div or 5 mVpp
> 10 mV/div DC to 2 GHz
0.6 div
Trigger sensitivity (external) 1 ± 1.6 V 40 mVpp DC to 100 MHz, 70 mVpp 100 to 200 MHz ± 8 V 200 mVpp DC to 100 MHz, 350 mVpp
100 to 200 MHz
Trigger level range Any channel
± 6 div from center screen
External 8-V range = ± 8 V; 1.6-V range =
± 1.6 V
Zone (hardware zone qualifier)
条件:Trigger on user-defined zones drawn on the display. Applies to one analog channel at a time.
Specify zones as either “must intersect” or “must not intersect.” Up to two zones. >
160,000 wfm/sec update rate
Supported modes: Normal, peak detect, high resolution, max update rate
Also works simultaneously with the serial decodes and mask limit test
Edge Trigger on a rising and falling edge of any source, alternating or either edge of analog and digital channels
Arm on a selected edge, wait a specified time, then trigger on a specified count of another selected edge. Minimum
4 ns
Trigger on a pulse on a selected channel, whose time duration is less than a value, greater than a value, or inside a
Minimum duration setting
2 ns
Maximum duration setting
10 s
Trigger when a specified pattern of high, low, and don’t-care levels on any combination of analog, digital, or trigger
channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as a valid trigger
条件:Or Trigger on any selected edges from available sources (analog and digital channels only).
Minimum duration setting
2 ns
Maximum duration setting
10 s
Trigger on rise time or fall time edge speed violations (< or >) based on user-selectable threshold. Select from (< or
Nth edge burst Trigger on the nth (1 to 65535) edge of a pulse burst. Specify idle time (10 ns to 10 s) for framing
条件:Setup and hold Trigger on setup/hold violations. Setup time can be set from –7 s to 10 s. Hold time can be set from 0 s to 10 ns.
Trigger on a position runt pulse that fails to exceed a high-level threshold. Trigger on a negative runt pulse that fails
to drop below a low-level threshold. Trigger on either polarity runt pulse based on two threshold settings. Runt
triggering can also be time-qualified (< or >) with a minimum time setting of 2 ns
Minimum window (setup time + hold time) must be
3 ns or greater
Video Trigger on all lines or individual lines, odd/even or all fields from composite video, or broadcast standards (NTSC,
Enhanced video (HDTV) (Option)
条件:conditions (parity, word, gap, word or gap, all), all bits (eye), all 0 bits, all 1 bits
Trigger on lines and fields of enhanced and HDTV standards (480p/60, 567p/50, 720p/50, 720p/60
1080p/24
1080p/25, 1080p/30, 1080p/50, 1080p/60, 1080i/50
1080i/60)
ARINC429 (Option) Trigger and decode on ARINC429 data. Trigger on word start/stop, label, label + bits, label range, error
条件:FlexRay (Option) Trigger on frame ID or specific error condition, along with cycle-base and repetition-cycle filtering. Can also trigger
Trigger on CAN (controller area network) version
2.0A,2.0B, and CAN-FD (Flexible Data-rate) signals. Trigger on
the start of frame (SOF), the end of frame (EOF), data frame ID, data frame ID and data (non-FD), data frame ID
and data (FD), remote frame ID, remote or data frame ID, error frame, acknowledge error, from error, stuff error,
CRC error, spec error (ack or form or stuff or CRC), all errors, BRS Bit (FD), CRC delimiter bit (FD), ESI bit active
Trigger type selections (FD), ESI bit passive (FD), overload frame., message, message and signal (non-FD), message and signal (FD, first
8 bytes only)
on specific events such as BSS, TSS, FES, and wake up
条件:I²C (Option) Trigger at a start/stop condition or user-defined frame with address and/or data values. Also trigger on missing
acknowledge, address with no acq, restart, EEPROM read, and 10-bit write
I²S (Option) Trigger on
2’s complement data of audio left channel or right channel (=, ≠, <, >, > <, < >, increasing value, or
LIN (Option) Trigger on LIN (Local Interconnect Network) sync break, sync frame ID, frame ID and data , parity error, or
MIL-STD1553
条件:conditions (parity, sync, Manchester)
Trigger on MIL-STD 1553 signals on data word start/stop, command/status start/stop, RTA, RTA +
11 bits, and error
Trigger on SPI (Serial Peripheral Interface) data pattern during a specific framing period. Supports positive and
negative Chip Select framing as well as clock Idle framing and user-specified number of bits per frame. Supports
UART/RS232/422/485
(Option) Trigger on Rx or Tx start bit, stop bit, data content, or parity error
Trigger on start of packet (SOP), end of packet (EOP), suspend***, resume***, reset***, packets (token, data,
handshake, or special), and errors (PID, CRC5, CRC16, glitch, bit stuff***, SE1***). Supports USB
2.0 low-speed
full- speed, and hi-speed implementations. (Hi-speed is supported on ≥
1-GHz models only)
Trigger and decode on SENT bus. start of fast channel message, start of slow channel message, fast channel SC
and data, slow channel message ID, slow channel message ID and data, tolerance violation, fast channel CRC
error, slow channel CRC error, all CRC errors, pulse period error, successive sync pulses error (1/64)
Trigger on start of frame (SOF), bus value, and Manchester errors
条件:messages, extended messages and value in HEX) 1. Suspend, resume, reset, bit stuff error, and SE1 error are USB 2.0 low - and full -speed only.
Trigger on the start of frame (SOF), the end of frame (EOF), PTYPE, frame ID, data and info frame ID, data and info
frame ID (long frame), CRC field error, parity error, inter-byte space error, inter-frame space error, framing error,
data length error, sample error, all errors, sleep frame, wakeup pulse
USB PD (Option) Trigger on preamble, EDP, ordered sets, preamble errors, CRC errors, header content (control messages, data
Search, navigate, and lister
Type Edge, pulse width, rise/fall, runt, frequency peak, serial bus 1, serial bus
2
Control Threshold, excursion, results order (frequency or amplitude)
Result display Event lister or navigation. Manual or autoscroll via navigation or touch event lister entry to
DC vertical accuracy/cursors
2
Single cursor accuracy: ± [DC vertical gain accuracy + DC vertical offset accuracy +
0.21% full scale]
Dual cursor accuracy: ± [DC vertical gain accuracy + 0.42% full scale]
1
Number of measurements
56 automatic measurements, maximum of 10 displayed at a time
Cursors
2 pairs of XY cursors
Automatic measurement of positions, ΔX
1/ΔX, ΔY, and ΔY/ΔX
Measurements continuously updated with statistics. Cursors track last selected
measurement. Select up to 10 measurements from the list below:
Snapshot Makes a snapshot of 31 most popular measurements. Touchable target to populate the
Peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, preshoot, average-
N cycles, average-full screen, DC RMS-N cycles, DC RMS-full screen, AC RMS-N cycles,
AC RMS-full screen (standard deviation), ratio-N cycles, ratio-full screen Y at X
Time Period, frequency, counter, + width, - width, burst width, + duty cycle, - duty cycle, bit rate,
rise time, fall time, delay, phase, X at min Y, X at max Y time at edge
Count Positive pulse count, negative pulse count, rising edge count, falling edge count
Mixed Area-N cycles, area-full screen slew rate
Jitter Option D6000USBB or D6000BDLB required
Data TIE, clock TIE, N-period, period-period, + width to + width, - width to - width
Real-time eye Option D6000USBB or D6000BDLB required
Dual-channel (requires N2820A probe)
Charge-N cycles, charge-full screen, peak-peak, amplitude, DC RMS-N cycles, DC RMS-
full screen, AC RMS- N cycles, AC RMS-full screen (standard deviation), average-N
cycles, average-full screen, base
Automatic measurement logging Available via BV0004B BenchVue
Built-in frequency counter (see “Precision counter/totalizer section” for the
10-digit
条件:1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30- minute warm -up period and ± 10
°C from firmware calibration temperature. 2. 1 mV/div is a magnification of 2 mV/div setting. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting.
Max frequency
1 GHz (1.2 GHz typical)
Number of math functions Four, displays all four simultaneously. Can be cascaded
Add, subtract, multiply, divide, differentiate, integrate, FFT, Ax + B, squared, square root,
absolute value, common logarithm, natural logarithm, exponential, base
10 exponential, low-
pass filter, high-pass filter, averaged value, magnify, max hold, min hold, measurement trend, chart logic bus (timing or state), clock recovery
Record size Up to 1-Mpts resolution via precision mode
Window types Hanning, flat top, rectangular, Blackman-Harris, Bartlett
波形 FFT, 最大 hold, 最小 hold, average
Peak search Max
11 peaks, threshold and excursion control
Standard mask limit test capability provides pass/fail comparison of a signal under test to a
predefined mask template or automask template. Predefined mask templates or edits to an
automask template can be made via a text editor. >
130,000 mask tests per second (waveform
Mask limit test Provides pass/fail analysis on selected parametric measurements based on user-defined
maximum and minimum limits with selectable stop-on-failure capability
Provides a statistical view of a waveform or a measurement
Source Any analog channels, math functions, reference waveforms, measurements
Types Horizontal, vertical, or measurement
Measurements Hits, peak, max, min, peak to peak, mean, median, mode, bin width, standard deviation
1~3
Provides a
3-dimensional view of waveform intensity
Source Any analog channels, math functions, reference waveforms, real-time eye
Measures the variance of a measurement over time
Jitter measurement floor
600 fs rms at 6 GHz sine wave (typical)
Source Any analog channels, math functions, and reference waveforms
Clock recovery Constant frequency, first-order phase lock loop (PLL), second-order PLL, explicit
Provides the color graded eye pattern analysis based on the recovered clock. Data bits are
folded on top of each other per clock cycle to give a
3-dimensional view
Source Any analog channels, math functions, and reference waveforms
Clock recovery Constant frequency, first-order phase lock loop (PLL), second-order PLL, explicit
Measurements Eye height, eye width
Precision mode Increase the analysis record length. Minimum: 100 kpts; maximum
1 Mpts
Precision counter/totalizer (Specifications are typical) (option)
Source Any analog channel or trigger qualified event
Resolution
10 digits (8 digits for trigger qualified event)
Max frequency Up to 3.2 GHz (4 GHz typical). With Hi-speed USB 2.0 decoding
1 GHz (1.2 GHz typical)
Trig-qual events 1/(trigger holdoff time) for trigger qualified events (max
25 MHz, minimum dead time of 40 ns)
Counter size
64-bit totalizing counter
Gating Positive or negative level. Select from analog channels except the source
Time reference Internal or external
10 MHz reference clock
Integrated digital voltmeter (Specification are typical) (option)
Source Analog channels only (1 ~
4)
Resolution ACV/DCV
3 digits
Counter frequency
5.5 digits
Measuring rate
100 times/second
Auto ranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements
Range meter Graphical display of most recent measurement, plus extreme over the previous
3 seconds
Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Option)
Both waveform generator outputs can be frequency tracked, amplitude tracked, or completely tracked. Phase adjustable.
1
A generator’s output can be inverted to create a differential signal
Output modes: Normal (continuous) or single-shot (limited to arbitrary, sine, ramp, sine cardinal, exp rise/fall, cardiac,
Waveforms Sine, square, ramp, pulse, DC, noise, sine cardinal (sinc), exponential rise, exponential fall, cardiac, Gaussian pulse, and
Modulation is available on channel 1 only. Modulation is not available when tracking mode is enabled
Carrier waveforms: sine, ramp, sine cardinal, exponential rise, exponential fall, and Cardiac.C176
Modulation source: Internal (no external modulation capability)
Modulation: Sine, square, ramp
Modulation frequency
1 Hz to 20 kHz
Modulation: Sine, square, ramp
Modulation frequency
1 Hz to 20 kHz
Minimum carrier frequency
10 Hz
Deviation
1 Hz to carrier frequency or (2e12/carrier frequency), whichever is smaller
条件:1. Only the following combination of wave shapes can be frequency tracked or completely tracked:
a. Sine, ramp, sine cardinal, cardiac, and Gaussian pulse. b. Square wave, and pulse. c. Exponential rise and exponential fall. d. Arbitrary.
Modulation
50% duty cycle square wave
Hop frequency
2x FSK rate to 10 MHz
Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (Continued)
Frequency range
0.1 Hz to 20 MHz
Amplitude flatness
± 0.5 dB (relative to 1 kHz)
Harmonic distortion
–40 dBc
Spurious (nonharmonics)
–40 dBc
Total harmonic distortion
1%
SNR (50 Ω load, 500 MHz BW) 40 dB (Vpp ≥ 0.1 V); 30 dB (Vpp <
0.1V)
Frequency range
0.1 Hz to 10 MHz
Duty cycle resolution Larger of 1% or 10 ns
Rise/fall time
19 ns (10 to 90%)
Asymmetry (at 50% DC) ± 1%
± 5 ns
Frequency range
0.1 Hz to 200 kHz
Variable symmetry
0 to 100%
Frequency range
0.1 Hz to 10 MHz
Pulse with resolution
10 ns
Edge time Fixed at 19 ns (not variable)
Noise Bandwidth
20 MHz typical
Sine cardinal (sinc) Frequency range
0.1 Hz to 1.0 MHz
Exponential rise/fall Frequency range
0.1 Hz to 5.0 MHz
Cardiac Frequency range
0.1 Hz to 200.0 kHz
Gaussian pulse Frequency range
0.1 Hz to 5.0 MHz
Waveform length
1 to 8,192 points
Amplitude resolution 10 bits (including sign bit)
1
Repetition rate
0.1 Hz to 12 MHz
条件:1. Full resolution is not available at output due to internal attenuator stepping.
Sine wave and ramp accuracy 130 ppm (frequency <
10 kHz)
50 ppm (frequency >
10 kHz)
Square wave and pulse accuracy [50 + frequency/200] ppm (frequency <
25 kHz)
50 ppm (frequency ≥
25 kHz)
Resolution
0.1 Hz or 4 digits, whichever is larger
Dual-channel WaveGen — built-in function/arbitrary waveform generator (Specification are typical) (continued)
Range: Minimum 20 mVpp if |offset| ≤ 0.5 Vpp into Hi-Z
1
10 mVpp if |offset| ≤ 0.5 Vpp into 50 Ω
1
Range: Maximum 10 Vpp except, 9 Vpp if sinc or cardiac
7.5 Vpp if Gaussian pulse into
Hi-Z; 5 Vpp/4.5 Vpp into
50 Ω
Resolution
100 μV or 3 digits, whichever is higher
Accuracy 1.5% (frequency =
1 kHz)
Range ± 5 V into Hi-Z, except ± 4 V if sine wave
± 2.5 V if sinc, cardiac, or
Gaussian pulse into Hi-Z ± 2.5 V into Hi-Z, except ± 2 V if sine wave, ± 1.25 V if sinc, cardiac, or Gaussian pulse into
50 Ω
Resolution Larger of 250 uV or 3 digits
Accuracy (waveform modes) ± 1.5% of offset setting ± 1% of amplitude
± 1 mV
Accuracy (DC mode) ± 1.5% of offset setting
± 3 mV
Quick action customization key
Quick measure all Displays a popup containing a snapshot of all the single waveform measurements
Quick measure statistics reset Resets all measurement statistics and the measurement count
Quick mask statistics reset Resets mask statistics and counters
Quick histogram statistics reset Zeros the histogram counters
Quick print Print the current screen image
Quick save Saves the current setup, screen image, or data file as specified in the settings menu
Quick email Emails the current setup, screen image, or data file as specified in the settings menu
Quick recall Recalls setup, mask, or reference waveform
Quick freeze display Freezes the display without stopping running acquisitions or unfreezes the display if
currently frozen. Waveform intensity preserved
Quick trigger mode Toggles the trigger mode between auto and normal
Display
12.1-inch capacitive multi-touch/gesture enabled color TFT LCD
Display mode Zone/zoom/annotation mode and waveform placement mode
Resolution 800 (H) x
600 (V) pixel format (screen area)
Graticules 8 vertical divisions by
10 horizontal divisions with intensity controls
条件:1. Sinc, cardiac and Gaussian pulse: ± 1.25 V into Hi- Z; ± 625 mV into 50 Ω.
Maximum waveform update rate >
135,000 wfm/s (real time)
> 450,000 wfm/s (real time max update rate)
Persistence Off, infinite, variable persistence (100 ms to 60 s)
Intensity gradation
256 intensity levels
USB 2.0 hi-speed host port USB 2.0 hi-speed host ports x3, two front and one real panel. Supports memory devices, printers
keyboards, mice, and USB microphones
USB 2.0 hi-speed device port One USB 2.0 hi-speed device port on rear panel. USB Test and Measurement Class (USBTMC)
LAN port
10/100/1000 Base-T port on rear panel. LXI IPv6 extended function
Web remote control VNC Web interface (via major Web browsers)
Video-out port VGA out on rear panel. Connect oscilloscope display to an external monitor or projector
GPIB port N4865A GPIB-to-LAN adapter (option)
10-MHz reference
Support mode Output and input off, output on (10-MHz out) input on (10-MHz in)
In mode 50 Ω, 356 mVpp to 4.48 Vpp (–5 dBm to 17 dBm)
6.32-Vpp max (20-dBm max)
Recommended input signal accuracy: better than
± 10 ppm
Out mode 50 Ω
1.65 Vpp square wave
Trigger out BNC connector on the rear panel. Supported modes: triggers, mask, waveform generator
1 sync pulse
and waveform generator
2 sync pulse
Power line consumption Maximum
200 W
Power voltage range 100-120 V, 50/60/400 Hz; 100-240 V
50/60 Hz
Environmental rating 0 to +50 °C
3962 m Max
Maximum Relative Humidity (non-condensing)
80%RH up to 40 °C
From 40 °C to 50 °C, the maximum % Relative Humidity follows the line of constant dew point
Meets EMC Directive (2004/108/EC), meets or exceeds IEC
61326-1:2005/EN
61326-1:2006 Group
1 Class A requirement
IEC 61000-4-2/EN
61000-4-2
IEC 61000-4-3/EN
61000-4-3
IEC 61000-4-4/EN
61000-4-4
IEC 61000-4-5/EN
61000-4-5
IEC 61000-4-6/EN
61000-4-6
IEC 61000-4-11/EN
61000-4-11
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS
Safety ANSI/UL Std. No. 61010-1:2012; CAN/CSA-C22.2 No.
61010-1-12
Vibration Meets IEC60068-2-6 and MIL-PRF-28800; class
3 random
Shock Meets IEC 60068-2-27 and MIL-PRF-28800; class 3 random; (operating 30 g, ½ sine, 11-ms duration
3
shocks/axis along major axis, total of 18 shocks)
Mean Time Before Failure (MTBF) >
120,000 hours
Dimensions 425 mm W x 288 mm H x
148 mm D
Weight Net: 6.8 kg (15 lbs.), Shipping
11.3 kg (25 lbs.)
Reference waveform display Four internal waveforms or USB thumb drive. Displays up to 4 reference waveforms
Setup/image Setup (*.scp), 8 or 24-bit bitmap image (*.bmp), PNG
24-bit image (*.png)
CSV data (*.csv), ASCII XY data (*.csv), binary data (*.bin), lister data (*.csv),
reference waveform data (*.h5), multichannel waveform data (*.h5), arbitrary
Application data Mask (*.msk), power harmonics data (*.csv), USB signal quality (*.html and *.bmp)
Analysis results (*.csv) Cursor data, measurement results, histogram statistics, mask test statistics, color
grade bin, search, segmented timestamps
Max USB flash drive size Supports industry-standard flash drives
Set ups without USB flash drive
10 internal setups
Soft copy of Certificate of Calibration (CoC) with measurement results downloadable
One per channel, N2894A
700-MHz passive probe (10:1 attenuation)
N2756A
16-digital-channel MSO cable (1 per oscilloscope included on all MSO models
and DSOX6MSO upgrade option)
Interface language support/built-in help
English, Chinese (simplified and traditional), French, German, Italian, Japanese,
Korean, Portuguese, Russian, and Spanish localized front-panel overlays, interface, and
English (American), English (British), English (Indian), Chinese Simplified (Mainland),
Chinese Simplified (Cantonese), Chinese Traditional (Taiwan), Chinese Traditional
(Cantonese), French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish
Front-panel protection Front-panel cover
Documentation CD containing localized user’s guide, service guide, and programmer’s manual
Publication title Publication number
Jitter Analysis - Application Note
5991-4000EN
Automotive Serial Bus Testing Using Keysight’s InfiniiVision X-Series and Infiniium S-Series Oscilloscopes
- Application Note
5991-4038EN
Physical Layer Testing of the USB 2.0 Serial Bus Using InfiniiVision
6000 X-Series and Infiniium Series Oscilloscopes
- Application Note
5991-4167EN
Evaluating Oscilloscopes for Low-Power Measurements - Application Note
5991-4268EN
InfiniiVision and Infiniium Oscilloscopes - Product Fact Sheet
5991-4273EN
Evaluating Current Probe Technologies for Low-Power Measurements - Application Note
5991-4375EN
Power Software Package - Data Sheet
5992-3925EN
Automotive Software Package - Data Sheet
5992-3912EN
Embedded Software Packag - Data Sheet
5992-3924EN
Aero Software Package - Data Sheet
5992-3910EN
USB Software Package - Data Sheet
5992-3920EN
Ultimate Bundle Software Package - Data Sheet
5992-3918EN
Download Your Next Insight
条件:we deliver the tools your team needs to accelerate from data to information to actionable insight.
Keysight software is downloadable expertise. From first simulation through first customer shipment,
For more information on Keysight Technologies’ products, applications , or services,
This information is subject to change without notice.© Keysight Technologies
2019 - 2026
Published in USA, January 30, 20 26, 5991-
4087 EN
• Multiple form factors from 50 MHz to 110 GHz
以上指标摘自厂家官方数据手册,完整定义、测试条件与保证值口径以手册为准。完整指标、测试条件与定义口径请见产品页「软件和手册 | 白皮书」栏目中的官方数据手册。
是德科技 | KEYSIGHT · onetest 仪器资源库