松田精密|Matsusada Precision Inc.
RE20-38-L(200V)-UL 直流电源 详细指标
Ultra Low Profile and High Power! Programmable DC Power Supply 20V / 38A / 760W
详细指标
以下指标取自松田精密(Matsusada Precision)官网 RE 系列产品页的「Models / Specifications / Options / Dimensions」区块,其中「型号输出参数」为该型号在官方型号表中的原始列值;官方原文为英文,此处按原文保留。详细规格与测试条件以官方数据手册为准。
型号输出参数
• Maximum Output / Voltage:20 V
• Current:38 A
• Power:0.76 kW
• Ripple / Voltage *1:10 mVrms
• Current *2:80 mArms
• Input voltage:200 V
系列共用规格
• Input voltage:100 Vac, 50/60 Hz, Single-phase (UL certified models)
200 Vac, 50/60 Hz, Single-phase (UL certified models)
200 Vac, 50/60 Hz, Three-phase (UL certified models)
115 Vac ±10%, 50/60 Hz, Single-phase
220 Vac ±10%, 50/60 Hz, Single-phase
230 Vac ±10%, 50/60 Hz, Single-phase
220 Vac ±10%, 50/60 Hz, Three-phase
400 Vac ±10%, 50/60 Hz, Three-phase (Option)
440 Vac ±10%, 50/60 Hz, Three-phase (Option)
• Output voltage control:[Local] Rotary encoder on front panel
[Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer
[Digital remote] Command (option)
• Output current control:[Local] Rotary encoder on front panel
[Analog remote] External control voltage 0 to 10 Vdc or external 10kΩ potentiometer
[Digital remote] Command (option)
• -LCP *2 *3:Constant power control
(Voltage control is disabled. Limited at maximum rated voltage)
• -LEt *2:LAN interface port
• -LGb *1:GPIB interface port (Scheduled for discontinuation in December 2028)
• -LGob *1 *2:Optical interface port
This option changes the standard interfaces to a built-in optical interface port. By combining this option with an adapter for optical connection (sold separately), communication between the control device and the power supply can be controlled in an isolated state. Be sure to select this option when using the product in the following environments.
-LGob: optical port + optical cable 2 meters
-LGob(Fc5): optical interface port + optical cable 5 meters
-LGob(Fc10): optical interface port + optical cable 10 meters
-LGob(Fc20): optical interface port + optical cable 20 meters
-LGob(Fc40): optical interface port + optical cable 40 meters
Select the optional build-in optical port (-LGob) when using this DC power supply under the following conditions.
Noisy environments such as factories (example: when motors or coils are used near loads or power sources).
If this power supply and your controller (PC or PLC) cannot be installed within 2 meters.
When there is a possibility of arcing or output short-circuit.
To use the optical interface, you need to prepare an optical interface adapter separately. For details, click here.
• Lls/-LIs10 *1:Isolated remote control
Output control signal is isolated from common (=outputΘ) so that floating of the control signal is not required when negative output operation or series connection
(isolation voltage from outputΘ is below 250 V)
Output control
[-LIs] CV: External control voltage 0 to 5 Vdc, CC: External control voltage 0 to 5 Vdc
[-LIs10] CV: External control voltage 0 to 10 Vdc, CC: External control voltage 0 to 10 Vdc
Monitor output
[-LIs] Output voltage monitor: 5 V/Maximum output voltage, Output current monitor: 5 V/Maximum output current
[-LIs10] Output voltage monitor: 10 V/Maximum output voltage, Output current monitor: 10 V/Maximum output current
Other functions
[-LIs/-LIs10] External output ON/OFF, Status signal output (CC, OUTPUT and Stand-by)
• -LLp:10-turn potentiometer with lock (both voltage and current)
Only for models less than 300 V
• -LOcp *4:Overcurrent protection (OCP)
Cut off the output at the set current value. Local setting only.
Setting range: 5% to 110% of maximum rated current, Local setting: 1-turn volume on front panel
Reset: Manual recovery by OUTPUT switch or External output ON/OFF
• -LPfc *4:Power factor correction circuit (Three-phase input of 3.75 kW to 15 kW type only)
Size of the case will be different. Contact the nearby sales office for more details about this option.
• -LUs1 *1:USB interface port
• -L(220V):Input voltage: 220 Vac ±10%
For 0.75 kW to 1.2 kW models, Replaces the standard 230 V input with 220 V input.
Input current will be about 105% of typical value
• -L(230V):Input voltage: 230 Vac ±10%
For 1.8 kW to 15 kW models, Replaces the standard 220 V input with 230 V input.
Input current will be about 95% of typical value
• -L(240V):Input voltage: 240 Vac ±10%
For the original input voltage of 220 V models, Change the input voltage to 240 V.
Input current will be about 95% of typical value
For the original input voltage of 230 V models, Change the input voltage to 240 V.
Input current will be about 90% of typical value
• -L(400V):Input voltage: 400 Vac ±10%
For 7.5 kW to 15 kW models
The size of the case will be different. Contact the nearby sales office for more details about this option.
• -L(440V):Input voltage: 440 Vac ±10%
For 7.5 kW to 15 kW models
The size of the case will be different. Contact the nearby sales office for more details about this option.
• Sweep control program for -LEt, -LGb, -LGob, -LUs1:This program allows for gradual output changes (ramp/sweep control) compatible with our digital controller adapters. Users can define start and end values for voltage and current, as well as the duration, to create custom output patterns. This feature is ideal for applications requiring specific voltage/current profiles, such as capacitor forming, electronic component aging, and semiconductor burn-in testing.
where it is necessary to repeat the output by changing the output gently and a decided pattern.
For more specification details, download the datasheet below.
• AC input cable:Included accessory
0.75 kW to 2.1 kW
Included with single-phase input models
CABLE TYPE5
250 V/25 A
2.5 meters
Additional accessory
1.8 kW to 3 kW
Included with three-phase input models
CABLE TYPE6
250 V/25 A
2.5 meters
Additional accessory
Available for 3.75 kW to 15 kW models
CABLE TYPE7
250 V/75 A
10 meters
Select an appropriate AC input cable according to your operating environment and region.
Please ask our sales offices for a three-phase input AC cable.
• Optical isolation adapter:To use the optical interface, you need to prepare an optical interface adapter separately. The following interface adapters are available according to your controller port.
CO-E32 : LAN to optical interface adapter
USB-OPT : USB to optical interface adapter
CO-OPT2-9 : RS-232C (9 pin) to optical interface adapter
CO-OPT2-25 : RS-232C (25 pin) to optical interface adapter
CO-OPT4-25 : RS-485 (25 pin) to optical interface adapter
CO-G32 : GPIB to optical interface adapter
(Scheduled for discontinuation in December 2028)
Example of communication with optical fiber
For details, refer to CO/USB series
• Application software:PSS2en series: Remote control, Test workflow design, and Data logging
PSS2en is the dedicated software that can actuate various power supplies, electronic loads, and digital controllers for power supplies manufactured by Matsusada Precision Inc. with a simple setup.
It is perfect for the aging test, the burn-in test, and the withstand voltage test for electronic parts, as well as for the endurance test, intermittent/continuous operation test, or various simulation tests for automobile electric components.
Click here for the PSS2en series
选件 / 附件
• -LCP *2 *3:Constant power control
(Voltage control is disabled. Limited at maximum rated voltage)
• -LEt *2:LAN interface port
• -LGb *1:GPIB interface port (Scheduled for discontinuation in December 2028)
• -LGob *1 *2:Optical interface port
This option changes the standard interfaces to a built-in optical interface port. By combining this option with an adapter for optical connection (sold separately), communication between the control device and the power supply can be controlled in an isolated state. Be sure to select this option when using the product in the following environments.
-LGob: optical port + optical cable 2 meters
-LGob(Fc5): optical interface port + optical cable 5 meters
-LGob(Fc10): optical interface port + optical cable 10 meters
-LGob(Fc20): optical interface port + optical cable 20 meters
-LGob(Fc40): optical interface port + optical cable 40 meters
Select the optional build-in optical port (-LGob) when using this DC power supply under the following conditions.
Noisy environments such as factories (example: when motors or coils are used near loads or power sources).
If this power supply and your controller (PC or PLC) cannot be installed within 2 meters.
When there is a possibility of arcing or output short-circuit.
To use the optical interface, you need to prepare an optical interface adapter separately. For details, click here.
• Lls/-LIs10 *1:Isolated remote control
Output control signal is isolated from common (=outputΘ) so that floating of the control signal is not required when negative output operation or series connection
(isolation voltage from outputΘ is below 250 V)
Output control
[-LIs] CV: External control voltage 0 to 5 Vdc, CC: External control voltage 0 to 5 Vdc
[-LIs10] CV: External control voltage 0 to 10 Vdc, CC: External control voltage 0 to 10 Vdc
Monitor output
[-LIs] Output voltage monitor: 5 V/Maximum output voltage, Output current monitor: 5 V/Maximum output current
[-LIs10] Output voltage monitor: 10 V/Maximum output voltage, Output current monitor: 10 V/Maximum output current
Other functions
[-LIs/-LIs10] External output ON/OFF, Status signal output (CC, OUTPUT and Stand-by)
• -LLp:10-turn potentiometer with lock (both voltage and current)
Only for models less than 300 V
• -LOcp *4:Overcurrent protection (OCP)
Cut off the output at the set current value. Local setting only.
Setting range: 5% to 110% of maximum rated current, Local setting: 1-turn volume on front panel
Reset: Manual recovery by OUTPUT switch or External output ON/OFF
• -LPfc *4:Power factor correction circuit (Three-phase input of 3.75 kW to 15 kW type only)
Size of the case will be different. Contact the nearby sales office for more details about this option.
• -LUs1 *1:USB interface port
• -L(220V):Input voltage: 220 Vac ±10%
For 0.75 kW to 1.2 kW models, Replaces the standard 230 V input with 220 V input.
Input current will be about 105% of typical value
• -L(230V):Input voltage: 230 Vac ±10%
For 1.8 kW to 15 kW models, Replaces the standard 220 V input with 230 V input.
Input current will be about 95% of typical value
• -L(240V):Input voltage: 240 Vac ±10%
For the original input voltage of 220 V models, Change the input voltage to 240 V.
Input current will be about 95% of typical value
For the original input voltage of 230 V models, Change the input voltage to 240 V.
Input current will be about 90% of typical value
• -L(400V):Input voltage: 400 Vac ±10%
For 7.5 kW to 15 kW models
The size of the case will be different. Contact the nearby sales office for more details about this option.
• -L(440V):Input voltage: 440 Vac ±10%
For 7.5 kW to 15 kW models
The size of the case will be different. Contact the nearby sales office for more details about this option.
• Sweep control program for -LEt, -LGb, -LGob, -LUs1:This program allows for gradual output changes (ramp/sweep control) compatible with our digital controller adapters. Users can define start and end values for voltage and current, as well as the duration, to create custom output patterns. This feature is ideal for applications requiring specific voltage/current profiles, such as capacitor forming, electronic component aging, and semiconductor burn-in testing.
where it is necessary to repeat the output by changing the output gently and a decided pattern.
For more specification details, download the datasheet below.
• AC input cable:Included accessory
0.75 kW to 2.1 kW
Included with single-phase input models
CABLE TYPE5
250 V/25 A
2.5 meters
Additional accessory
1.8 kW to 3 kW
Included with three-phase input models
CABLE TYPE6
250 V/25 A
2.5 meters
Additional accessory
Available for 3.75 kW to 15 kW models
CABLE TYPE7
250 V/75 A
10 meters
Select an appropriate AC input cable according to your operating environment and region.
Please ask our sales offices for a three-phase input AC cable.
• Optical isolation adapter:To use the optical interface, you need to prepare an optical interface adapter separately. The following interface adapters are available according to your controller port.
CO-E32 : LAN to optical interface adapter
USB-OPT : USB to optical interface adapter
CO-OPT2-9 : RS-232C (9 pin) to optical interface adapter
CO-OPT2-25 : RS-232C (25 pin) to optical interface adapter
CO-OPT4-25 : RS-485 (25 pin) to optical interface adapter
CO-G32 : GPIB to optical interface adapter
(Scheduled for discontinuation in December 2028)
Example of communication with optical fiber
For details, refer to CO/USB series
• Application software:PSS2en series: Remote control, Test workflow design, and Data logging
PSS2en is the dedicated software that can actuate various power supplies, electronic loads, and digital controllers for power supplies manufactured by Matsusada Precision Inc. with a simple setup.
It is perfect for the aging test, the burn-in test, and the withstand voltage test for electronic parts, as well as for the endurance test, intermittent/continuous operation test, or various simulation tests for automobile electric components.
Click here for the PSS2en series
资源下载
以上规格取自松田精密(Matsusada Precision)官网 RE 系列产品页(https://www.matsusada.com/product/dc-power-supplies/rack/re/)。
松田精密(Matsusada Precision) · onetest 仪器资源库